Read Sharp LC-32GD1E (serv.man6) Service Manual online

16
LC-32GD1E
LC-37GD1E
 Precautions in handling the LCD panel
1. Handle the liquid crystal panel in a clean room (Humidity: 50% or more).
2. Be sure to wear an earth wristband.
3. Be careful not to drop and shock the liquid crystal panel.
4. Use an ionizer (within 30 cm).
25. Remove the 5 screws 
k
 (LX-BZA051WJFN).
26. Remove the LCD panel unit.
27. Remove the 8 screws 
l
 (XBPSN30P06000).
28. Remove the sheet presser angles.
29. Remove the 6 screws 
;
 (XBPSN30P10000).
30. Remove the sheet presser angles.
31. Detach the Reflection/Deflection Sheet, Prism Sheet, Diffusion Sheet, and Diffusion Plate.
32. Remove the 6 screws 
31
 (XBBSN30P08000).
33. Remove the Lamp Holders (top).
34. Detach the Lamps.
*
The Reflection Plate (PMIR-S041WJZZ) is attached to the Backlight Chassis using clips and two-sided tape, and
it cannot be disassembled.
LCD Panel Unit
Diffusion Panel
Diffusion Sheet
Sheet Presser Angle
Lamp Holder (Top)
Lamp
Lamp Holder (Top)
Lamp Holder (Bottom)
Backlight Chassis
Lamp Holder (Bottom)
28
29
30
29
31
31
30
Reflection/Deflection Sheet
Prism Sheet