XV-Z21000 (serv.man3). Troubleshooting Table - Sharp Projector Service Manual (repair manual). Page 8

Read Sharp XV-Z21000 (serv.man3) Service Manual online

XV-Z20000/XV-Z21000/DT-5000
5 – 8
Check the synchronization signal.
Is the signal generator (input source) 
set correctly?
NO
Set the signal generator (input source) 
correctly.
YES
Is a vertical synchronization signal 
present at TL5505?
NO
Peripheral circuits of IC5502 and 5503 are 
defective.
Or the main unit is defective.
YES
Is a horizontal synchronization signal 
present at TL5504?
NO
 Peripheral circuits of IC5502 and 5503 
are defective.
Or the main unit is defective.
YES
Is a vertical synchronization signal 
present at TL5515?
NO
The IC5504, IC5510 or IC5511 peripheral 
parts are defective.
YES
Is a horizontal synchronization signal 
present at TL5509?
NO
The IC5504, IC5510 or IC5511 peripheral 
parts are defective.
YES
Synchronization signals are normal.
IC5652 peripheral check
Set the signal generator to output a 
RAMP signal.
Is a synchronization signal present at 
R5610 and TL5515?
NO
The IC5511 peripheral parts or IC6001 
(CVIC) are defective.
YES
Is a clock signal present at R5679?
NO
 The IC5652 clock oscillation circuit or 
IC5652 is defective.
YES
Are video signals sent to TL5655? 
TL5661?
NO
The IC5209 peripheral circuit or the main 
unit is defective.
YES
Is a pulse present at pins (28) - (63) 
of IC5652?
NO
IC5652 is defective.
YES
IC6001 (CVIC) is defective.