XV-Z21000 (serv.man3). Troubleshooting Table - Sharp Projector Service Manual (repair manual). Page 6

Read Sharp XV-Z21000 (serv.man3) Service Manual online

XV-Z20000/XV-Z21000/DT-5000
5 – 6
Check OSD.
Press the key on the main unit or the 
[MENU] key on the remote control. 
Is the menu display brought up?
YES
END
NO
Is there a clock signal at TL6618?
NO
Is a clock signal (74.25MHz) present at 
TL6007?
NO
Check peripoheral circuits of 
IC6001.
YES
YES
Is there a clock signal at TL6006
NO
X6002 is defective.
YES
Check peripoheral circuits of IC6001
Is a synchronization signal present at 
TL6617, TL6620-21?
NO
Check the bus signal between IC5003 
and IC6001.
YES
Check TL6622, TL6619 using an 
oscilloscope. Is the signal seen cor-
rect?
YES
The connector CN6604 or FPC and for-
matter unit are defective.
NO
IC6001 (CVIC) is defective. 
Page of 15