XV-Z21000 (serv.man3). Troubleshooting Table - Sharp Projector Service Manual (repair manual). Page 12

Read Sharp XV-Z21000 (serv.man3) Service Manual online

XV-Z20000/XV-Z21000/DT-5000
5 – 12
Check the 
VIDEO syn-
chronization 
signal.
Is a vertical syn-
chronization sig-
nal present at 
TL5710?
NO
Is a clock signal 
(24.57 MHz) 
present at 
X5701?
Check the voltage 
output of IC5702 
and 
IC5703.X5701 or 
IC5706 is defec-
tive.
YES
NO
Is a horizontal 
synchronization 
signal present at 
TL5711?
NO
YES
YES
The VIDEO syn-
chronization sig-
nal is normal.
Is a video signal 
present at 
TL5712?
YES
IC5706 is defec-
tive.
NO
Is the input signal 
525iRGB (or com-
ponent)?
YES
Is a video signal 
present at 
TL5703?
YES
IC5706 is defec-
tive.
NO
NO
Check peripheral 
circuits of Q5701 
and Q5707.
The main unit is 
defective.
Is the input signal 
composite VIDEO 
(CVBS)?
YES
Is a video signal 
present at 
TL5707?
YES
Is S-VIDEO pro-
jected normally?
NO
IC5706 is defec-
tive.
NO
NO
YES
Check peripheral 
circuits of Q5706 
and Q5712.
The main unit is 
defective.
Check peripheral 
circuits of IC5707.
Is the input signal 
S-VIDEO?
YES
Are video signals 
sent to TL5705 
and TL5706?
YES
IC5706 is defec-
tive.
NO
Check peripheral 
circuits of Q5704, 
Q5705, Q5710 
and Q5711.
The main unit is 
defective.
Page of 15