XV-Z21000 (serv.man3). Troubleshooting Table - Sharp Projector Service Manual (repair manual). Page 5

Read Sharp XV-Z21000 (serv.man3) Service Manual online

XV-Z20000/XV-Z21000/DT-5000
5 – 5
Check the PC PWB unit.
Can the menu display be 
brought up?
YES
Check the RGB input.
Check the basic flow of the signals. 
Since the component and VIDEO signals follow the 
same path to the output as the formatter unit uses, 
after CVIC (IC6001), the check that would otherwise 
be performed after the CVIC does not need to be per-
formed. (480i and 576i are excluded.)
NO
Check OSD.
Check the input at the compo-
nents.
The signal passes through the same circuit as the 
RGB input. Mainly, check the SOG (Sync On Green) 
circuit and the color adjustment circuit. (480i and 576i 
are excluded.)
Check the VIDEO input.
Since the VIDEO input enters CVIC through a different 
route than the RGB input, check the VIDEO IC. 
(480i and 576i are excluded.)
Check the 480iRGB (or com-
ponent) input.
The video signal and the color signal pass through the 
same circuits as the RGB input. However, since the 
synchronization signal uses the VIDEO IC, 
check the synchronization signal path.
Check the DVI analog input.
Check the DVI digital/HDMI 
input.
The signal is reproduced in an IC specially designed 
for use with the TMDS, and it enters the CVIC.
END