XV-Z21000 (serv.man3). Troubleshooting Table - Sharp Projector Service Manual (repair manual). Page 13

Read Sharp XV-Z21000 (serv.man3) Service Manual online

XV-Z20000/XV-Z21000/DT-5000
5 – 13
IC5706 peripheral check
Is a clock signal (24.57 MHz) present 
at X5701?
NO
Check X5701, or IC5706 is defective.
YES
Is a clock signal present at TL5712?
NO
IC5706 is defective.
YES
Supply a RAMP signal to VIDEO, and 
observe pins (86 - 100) of 
IC5706using an oscilloscope.
Is a pulse present at pins (86 - 100) of 
IC5706?
NO
IC5706 is defective.
YES
Supply a color bar signal to VIDEO, 
and observe pins (112 - 122) of 
IC5706.
Is a pulse present at pins (112 - 122) 
of IC5706?
NO
IC5706 is defective.
YES
IC6001 or after is defective.