No.
Adjusting point
Adjusting conditions
Adjusting procedure
4
RGB2 system
black level
signal amplitude
adjustment
black level
signal amplitude
adjustment
»
Select R2-GAIN. Adjust the setting so that the
signal component has the minimum amplitude.
signal component has the minimum amplitude.
1. Select the following group
and subjects.
Group : OUTPUT2
Subject : R2-GAIN
Group : OUTPUT2
Subject : R2-GAIN
R2-BLK
For the G and B colors,
choose the following re-
spective subjects.
G2-GAIN and G2-BLK for G
B2-GAIN and B2-BLK for B
choose the following re-
spective subjects.
G2-GAIN and G2-BLK for G
B2-GAIN and B2-BLK for B
2. Connect the oscilloscope to
pin (2) (for R) of P1001.
3. Similarly connect the oscil-
loscope to the following for
the G and B colors.
Pin (4) of P1001 for G
Pin (6) of P1001 for B
the G and B colors.
Pin (4) of P1001 for G
Pin (6) of P1001 for B
»
Select R2-BLK. Adjust the setting so that the wave-
form becomes a straight horizontal line.
form becomes a straight horizontal line.
Adjusted to
5
Sample hold
pulse phase
checking
pulse phase
checking
»
Using the set's control switch or the remote
controller’s button, make sure the characters
OUTPUT3 are not blurry with no ghost image on
the screen. If anything blurry or a ghost image
appears onscreen, readjust the setting in the
range of 7-9.
controller’s button, make sure the characters
OUTPUT3 are not blurry with no ghost image on
the screen. If anything blurry or a ghost image
appears onscreen, readjust the setting in the
range of 7-9.
1. Feed the XGA-mode, 75-
Hz black signal.
2. Select the following group
and subject.
Group : OUTPUT3
Subject : SH-PHASE
Group : OUTPUT3
Subject : SH-PHASE
6
RGB
countervoltage
adjustment
countervoltage
adjustment
»
Using the set's control switch or the remote
controller’s button, adjust the setting so that the
flickering be minimum.
controller’s button, adjust the setting so that the
flickering be minimum.
»
If there is a difference between the center and
both sides on the screen, adjust the setting to get
both sides equal to each other.
both sides on the screen, adjust the setting to get
both sides equal to each other.
1. Feed the XGA-mode, 60-
Hz, countervoltage adjust-
ment signal.
ment signal.
2. Select the following group
and subjects.
Group : OUTPUT3
Subject : RC (R)
Group : OUTPUT3
Subject : RC (R)
GC (G)
BC (B)
BC (B)
7
RGB tone
reproduction
adjustment
reproduction
adjustment
»
Make sure the grayscale, shown below, is visible
up to the tone 251 (white) as well as down to the
tone 8 (black).
up to the tone 251 (white) as well as down to the
tone 8 (black).
»
If the white tone is out of spec, finely adjust the
G1-BLK setting.
G1-BLK setting.
1. Feed the Infocom
Grayscale & Color Pattern
signal.
signal.
2. Select the following group
and subject.
Group : OUTPUT1
Subject : G1-BLK
Group : OUTPUT1
Subject : G1-BLK
4