XG-NV2E (serv.man5). Supplement service manual 2 - Sharp Projector Service Manual (repair manual). Page 3

Read Sharp XG-NV2E (serv.man5) Service Manual online

3
XG-NV2U/E/M
SUPPLEMENT
3. Repair procedure
Interconnecting 1:Production lot in December 1997
Fan Control PWB (Display; K9661DE without 
.)
QCNW-4978CEZZ
QCNW-4979CEZZ
QCNW-4982CEZZ       QCNW-4983CEZZ
OUTPUT PWB 
OUTPUT sub PWB 
1
1
Trouble spot
Preparations
Procedure
Fan Control PWB
Output sub-PWB
DUNTK9567DE
Output PWB
DUNTK5926DE
Fan Control PWB marked "A"
QCNW-4980CEZZ (with UL tape)
QCNW-4981CEZZ
When replace with the Output sub-
PWB
:
Fan PWB marked "A"
QCNW-4980CEZZ (with UL tape)
QCNW-5001CEZZ
Both Output PWB 
 and 
 can be
used.
Disconnect the QCNW-4978CEZZ, -4979CEZZ, -
4982CEZZ and -4983CEZZ cables, and connect the
QCNW-4980CEZZ and -4981CEZZ cables.
Disconnect the Output sub-PWB, Fan Control PWB,
QCNW-4978CEZZ, -4979CEZZ, -4983CEZZ cable,
and connect a new Output sub-PWB 
, Fan Control
PWB marked "A", QCNW-4980CEZZ and QCNW-
5001CEZZ cable. Disconnect QCNW-4983CEZZ ca-
ble from Output PWB.
Disconnect QCNW-4983CEZZ cable from the defec-
tive PWB , and connect to the new PWB.
Interconnecting 2:Production lot in January 1998
Fan Control PWB (Display; S9661CE 
.)
QCNW-4980CEZZ
QCNW-4981CEZZ
Output sub PWB 
1
1
Trouble spot
Preparations
Procedure
Fan Control PWB
Output sub-PWB
DUNTK9567DE
Output PWB
DUNTK5926DE
Fan Control PWB marked "A"
When replace with the Output sub-
PWB
:
QCNW-5001CEZZ cable
Both Output PWB 
 and 
 can be
used.
Replace Fan Control PWB marked "A".
Connect a new Output sub-PWB 
 and QCNW-
5001CEZZ cable.
Replace the Output PWB as it is.
When replace with the Output sub-PWB
, disconnect the defective PWB from QCNW-
4981CEZZ cable, and connect the new PWB.
When replace with the Output sub-PWB
, disconnect the defective PWB from QCNW-
4979CEZZ cable, and connect the new PWB..
1
1
2
2
2
2
1
1
2
2
Page of 12