XG-NV2E (serv.man5). Supplement service manual 2 - Sharp Projector Service Manual (repair manual). Page 2

Read Sharp XG-NV2E (serv.man5) Service Manual online

2
XG-NV2U/E/M
SUPPLEMENT
1.Interconnecting the Fan Control PWB and the output sub-PWB
Here are the three basic ways.
<1> Production lot in December 1997
Fan Control PWB (Display; K9661DE without 
.)
QCNW-4978CEZZ
QCNW-4979CEZZ
QCNW-4982CEZZ       QCNW-4983CEZZ
OUTPUT PWB 
OUTPUT sub PWB 
1
1
<2> Production lot in January 1998
Fan Control PWB (Display; S9661CE 
.)
QCNW-4980CEZZ
QCNW-4981CEZZ
Output sub PWB 
1
1
<3> Production lot in February 1998 and on
1
 
Checking the fan control PWB
Turn on the projector power, 
but the projector turns itself 
off 2-3 seconds later.
Disconnect the relay connector 
from the fan control PWB.
Fan control 
PWB defective.
Fan 
operated.
Other part 
than the fan 
control PWB 
defective.
Fan 
unoperated.
2
 
Checking for a fan trouble
Disconnect the lead from the 
running fan.
Fan control 
PWB 
defective.
Fan still 
running
No problem.
Fan 
interrupted
3
 
Checking for a fan trouble
Get the running fan locked.
Fan control 
PWB 
defective.
Fan still 
running
No problem.
Fan 
interrupted
 2. Troubleshooting for the Fan Control PWB
Precautions
* Some Fan Control PWBs are provided with a wire holder instead of the insulator lock. After repairing such a PWB,
remove the wire holder and bundle the wires with the insulator lock. If the insulator lock is cut off for repair purpose,
bundle the wires with a new insulator lock. (CE measures) Part code: LHLDW1033CEZZ
* If the output PWB has been replaced, readjustment is needed.
Fan Control PWB (Display; S9661CE 
,F0136AD 
.)
QCNW-4980CEZZ
QCNW-5001CEZZ
Output sub PWB 
1
0
2