1.Interconnecting the Fan Control PWB and the output sub-PWB
Here are the three basic ways.
<1> Production lot in December 1997
<1> Production lot in December 1997
Fan Control PWB (Display; K9661DE without
√
.)
QCNW-4978CEZZ
QCNW-4979CEZZ
QCNW-4982CEZZ QCNW-4983CEZZ
OUTPUT PWB
√
OUTPUT sub PWB
√
1
1
<2> Production lot in January 1998
Fan Control PWB (Display; S9661CE
√
.)
QCNW-4980CEZZ
QCNW-4981CEZZ
Output sub PWB
√
1
1
<3> Production lot in February 1998 and on
1
Checking the fan control PWB
Turn on the projector power,
but the projector turns itself
off 2-3 seconds later.
but the projector turns itself
off 2-3 seconds later.
Disconnect the relay connector
from the fan control PWB.
from the fan control PWB.
Fan control
PWB defective.
PWB defective.
Fan
operated.
operated.
Other part
than the fan
control PWB
defective.
than the fan
control PWB
defective.
Fan
unoperated.
unoperated.
2
Checking for a fan trouble
Disconnect the lead from the
running fan.
running fan.
Fan control
PWB
defective.
PWB
defective.
Fan still
running
running
No problem.
Fan
interrupted
interrupted
3
Checking for a fan trouble
Get the running fan locked.
Fan control
PWB
defective.
PWB
defective.
Fan still
running
running
No problem.
Fan
interrupted
interrupted
2. Troubleshooting for the Fan Control PWB
Precautions
* Some Fan Control PWBs are provided with a wire holder instead of the insulator lock. After repairing such a PWB,
* Some Fan Control PWBs are provided with a wire holder instead of the insulator lock. After repairing such a PWB,
remove the wire holder and bundle the wires with the insulator lock. If the insulator lock is cut off for repair purpose,
bundle the wires with a new insulator lock. (CE measures) Part code: LHLDW1033CEZZ
bundle the wires with a new insulator lock. (CE measures) Part code: LHLDW1033CEZZ
* If the output PWB has been replaced, readjustment is needed.
Fan Control PWB (Display; S9661CE
√
,F0136AD
√
,
√
.)
QCNW-4980CEZZ
QCNW-5001CEZZ
Output sub PWB
√
1
0
2
2