Read Sharp XG-NV2E (serv.man5) Service Manual online
1
XG-NV2U/E/M
SUPPLEMENT
SHARP CORPORATION
SERVICE MANUAL
SERVICE-ANLEITUNG
SERVICE-ANLEITUNG
S70E3XG-NV2U/
PAL/SECAM/NTSC SYSTEM
LCD PROJECTOR
SUPPLEMENT
In the interests of user-safety (Required by safety regulations in some countries) the set should be restored
to its original condition and only parts identical to those specified should be used.
to its original condition and only parts identical to those specified should be used.
Im lnteresse der Benutzersicherheit (erforderliche Sicherheitsregeln in einigen Ländern) muß das Gerät in seinen
Originalzustand gebracht werden. Außerdem dürfen für die spezifizierten Bauteile nur identische Teile verwendet
werden.
Originalzustand gebracht werden. Außerdem dürfen für die spezifizierten Bauteile nur identische Teile verwendet
werden.
MODELS
MODELLE
MODELLE
OUTLINE
XG-NV2U
XG-NV2E
XG-NV2M
XG-NV2E
XG-NV2M
This Service Manual Supplement covers the fan control PWB, output sub-PWB and output PWB, and their
combinations. These PWBs come in different versions depending on the production lots. Some types of PWBs
may be incompatible with each other. In replacing or repairing those PWBs, refer to this Supplement for proper
combinations.
combinations. These PWBs come in different versions depending on the production lots. Some types of PWBs
may be incompatible with each other. In replacing or repairing those PWBs, refer to this Supplement for proper
combinations.
ABRISS
Diese Ergänzung zum Wartungshandbuch behandelt die Ventilator-Zusatzplatine, die Ausgangs-Zusatzplatine
sowie die Ausgangsplatine und ihre Kombinationen. Diese Platinen werden in verschiedenen Ausführungen
geliefert, was wiederum von der jeweiligen Produktionsserie abhängt. Einige Platinentypen können miteinander
inkompatibel werden. Für das Auswechseln oder die Reparatur dieser Platinen beziehen Sie sich zwecks der
passenden Kombinationen bitte auf diese Ergänzung.
sowie die Ausgangsplatine und ihre Kombinationen. Diese Platinen werden in verschiedenen Ausführungen
geliefert, was wiederum von der jeweiligen Produktionsserie abhängt. Einige Platinentypen können miteinander
inkompatibel werden. Für das Auswechseln oder die Reparatur dieser Platinen beziehen Sie sich zwecks der
passenden Kombinationen bitte auf diese Ergänzung.
CONTENTS / INHALT
Page
Seite
1.Interconnecting the Fan Control PWB and the
output sub-PWB ................................................. 2
2.Troubleshooting for the Fan Control PWB .......... 2
3.Repair procedure ................................................ 3
4.Others ................................................................ 4
5.Connecting the QCNW-4979CEZZ cable leads
3.Repair procedure ................................................ 3
4.Others ................................................................ 4
5.Connecting the QCNW-4979CEZZ cable leads
on the output sub-PWB ...................................... 8
6.Connecting the QCNW-4981CEZZ cable leads
on the output sub-PWB ...................................... 9
• PARTS LIST ..................................................... 10
1.Ausstellung eines technischen Berichts
hinsichtlich der Ventilator-Zusatzplatine ............. 5
2.Störungssuche für die Ventilator-Zusatzplatine .. 5
3.Reparaturverfahren ............................................ 6
4.Weiteres ............................................................. 7
5.Anschließen der QCNW-4979CEZZ-Kabel an
3.Reparaturverfahren ............................................ 6
4.Weiteres ............................................................. 7
5.Anschließen der QCNW-4979CEZZ-Kabel an
der Ausgangs-Zusatzplatine ............................... 8
6.Anschließen der QCNW-4981CEZZ-Kabel an
der Ausgangs-Zusatzplatine ............................... 9
• ERSATZTEILLISTE .......................................... 10
2
XG-NV2U/E/M
SUPPLEMENT
1.Interconnecting the Fan Control PWB and the output sub-PWB
Here are the three basic ways.
<1> Production lot in December 1997
<1> Production lot in December 1997
Fan Control PWB (Display; K9661DE without
√
.)
QCNW-4978CEZZ
QCNW-4979CEZZ
QCNW-4982CEZZ QCNW-4983CEZZ
OUTPUT PWB
√
OUTPUT sub PWB
√
1
1
<2> Production lot in January 1998
Fan Control PWB (Display; S9661CE
√
.)
QCNW-4980CEZZ
QCNW-4981CEZZ
Output sub PWB
√
1
1
<3> Production lot in February 1998 and on
1
Checking the fan control PWB
Turn on the projector power,
but the projector turns itself
off 2-3 seconds later.
but the projector turns itself
off 2-3 seconds later.
Disconnect the relay connector
from the fan control PWB.
from the fan control PWB.
Fan control
PWB defective.
PWB defective.
Fan
operated.
operated.
Other part
than the fan
control PWB
defective.
than the fan
control PWB
defective.
Fan
unoperated.
unoperated.
2
Checking for a fan trouble
Disconnect the lead from the
running fan.
running fan.
Fan control
PWB
defective.
PWB
defective.
Fan still
running
running
No problem.
Fan
interrupted
interrupted
3
Checking for a fan trouble
Get the running fan locked.
Fan control
PWB
defective.
PWB
defective.
Fan still
running
running
No problem.
Fan
interrupted
interrupted
2. Troubleshooting for the Fan Control PWB
Precautions
* Some Fan Control PWBs are provided with a wire holder instead of the insulator lock. After repairing such a PWB,
* Some Fan Control PWBs are provided with a wire holder instead of the insulator lock. After repairing such a PWB,
remove the wire holder and bundle the wires with the insulator lock. If the insulator lock is cut off for repair purpose,
bundle the wires with a new insulator lock. (CE measures) Part code: LHLDW1033CEZZ
bundle the wires with a new insulator lock. (CE measures) Part code: LHLDW1033CEZZ
* If the output PWB has been replaced, readjustment is needed.
Fan Control PWB (Display; S9661CE
√
,F0136AD
√
,
√
.)
QCNW-4980CEZZ
QCNW-5001CEZZ
Output sub PWB
√
1
0
2
2
3
XG-NV2U/E/M
SUPPLEMENT
3. Repair procedure
Interconnecting 1:Production lot in December 1997
Fan Control PWB (Display; K9661DE without
√
.)
QCNW-4978CEZZ
QCNW-4979CEZZ
QCNW-4982CEZZ QCNW-4983CEZZ
OUTPUT PWB
√
OUTPUT sub PWB
√
1
1
Trouble spot
Preparations
Procedure
Fan Control PWB
Output sub-PWB
DUNTK9567DE
DUNTK9567DE
Output PWB
DUNTK5926DE
DUNTK5926DE
Fan Control PWB marked "A"
QCNW-4980CEZZ (with UL tape)
QCNW-4981CEZZ
QCNW-4980CEZZ (with UL tape)
QCNW-4981CEZZ
When replace with the Output sub-
PWB
PWB
√
:
Fan PWB marked "A"
QCNW-4980CEZZ (with UL tape)
QCNW-5001CEZZ
QCNW-4980CEZZ (with UL tape)
QCNW-5001CEZZ
Both Output PWB
√
and
√
can be
used.
Disconnect the QCNW-4978CEZZ, -4979CEZZ, -
4982CEZZ and -4983CEZZ cables, and connect the
QCNW-4980CEZZ and -4981CEZZ cables.
4982CEZZ and -4983CEZZ cables, and connect the
QCNW-4980CEZZ and -4981CEZZ cables.
Disconnect the Output sub-PWB, Fan Control PWB,
QCNW-4978CEZZ, -4979CEZZ, -4983CEZZ cable,
and connect a new Output sub-PWB
QCNW-4978CEZZ, -4979CEZZ, -4983CEZZ cable,
and connect a new Output sub-PWB
√
, Fan Control
PWB marked "A", QCNW-4980CEZZ and QCNW-
5001CEZZ cable. Disconnect QCNW-4983CEZZ ca-
ble from Output PWB.
5001CEZZ cable. Disconnect QCNW-4983CEZZ ca-
ble from Output PWB.
Disconnect QCNW-4983CEZZ cable from the defec-
tive PWB , and connect to the new PWB.
tive PWB , and connect to the new PWB.
Interconnecting 2:Production lot in January 1998
Fan Control PWB (Display; S9661CE
√
.)
QCNW-4980CEZZ
QCNW-4981CEZZ
Output sub PWB
√
1
1
Trouble spot
Preparations
Procedure
Fan Control PWB
Output sub-PWB
DUNTK9567DE
DUNTK9567DE
Output PWB
DUNTK5926DE
DUNTK5926DE
Fan Control PWB marked "A"
When replace with the Output sub-
PWB
PWB
√
:
QCNW-5001CEZZ cable
Both Output PWB
√
and
√
can be
used.
Replace Fan Control PWB marked "A".
Connect a new Output sub-PWB
√
and QCNW-
5001CEZZ cable.
Replace the Output PWB as it is.
When replace with the Output sub-PWB
√
, disconnect the defective PWB from QCNW-
4981CEZZ cable, and connect the new PWB.
When replace with the Output sub-PWB
√
, disconnect the defective PWB from QCNW-
4979CEZZ cable, and connect the new PWB..
1
1
2
2
2
2
1
1
2
2
4
XG-NV2U/E/M
SUPPLEMENT
Interconnecting 3:Production lot in February 1998 and on
Trouble spot
Preparations
Procedure
Fan Control PWB
Output sub-PWB
DUNTK9567DE
DUNTK9567DE
Output PWB
DUNTK9526DE
DUNTK9526DE
Fan Control PWB marked "A"
When replace with the Output sub-
PWB
PWB
√
:
QCNW-4981CEZZ cable
Both Output PWB
√
and
√
can be
used.
Replace Fan Control PWB marked "A".
Disconnect Output sub PWB and QCNW-5001CEZZ
cable, and connect QCNW-4981CEZZ cable to a new
Output sub PWB
cable, and connect QCNW-4981CEZZ cable to a new
Output sub PWB
√
.
Replace the Output PWB as it is.
Fan Control PWB (Display; S9661CE
√
,F0136AD
√
,
√
.)
QCNW-4980CEZZ
QCNW-5001CEZZ
Output sub PWB
√
1
0
2
2
When replace with the Output sub-PWB
√
, disconnect the defective PWB from QCNW-
5001CEZZ cable, and connect the new PWB.
4. Others
1
The replacement fan control PWB is marked "A" on its back. PWBs of this type are manufactured as from
February 1998 (redesigned to upgrade the standby mode when the main power is turned on).
February 1998 (redesigned to upgrade the standby mode when the main power is turned on).
2
The replacement QCNW-4980CEZZ cable has UL tape attached.
The UL tape is applied to prevent the cable from getting caught by the side panel-to-top panel screw-down
bracket. See below for the tape position.
The UL tape is applied to prevent the cable from getting caught by the side panel-to-top panel screw-down
bracket. See below for the tape position.
1 Brown
2 Brown
3 Brown
4 Brown
5 Brown
3 Brown
4 Brown
5 Brown
Brown 1
Brown 2
Brown 3
Brown 4
Brown 5
Brown 3
Brown 4
Brown 5
260
±
5
10
50
±
5
PHR-5
(2-mm-pitch
socket)
(2-mm-pitch
socket)
SMP-05V-NC
(2.5-mm-pitch
relay connector)
(2.5-mm-pitch
relay connector)
Output sub-PWB side
Fan Control PWB side
UL tape added here
2
2
1
1
1