XG-MB67X (serv.man3). Troubleshooting Table - Sharp Projector Service Manual (repair manual). Page 11

Read Sharp XG-MB67X (serv.man3) Service Manual online

XG-MB67X
8 – 11
Checking the LAN
LAN communication is disabled even 
though connecting the control PC with a 
LAN cable. The LINK LED (green) does not 
light up.
YES
Are the connection of connecting cable and 
the settings of IP address, sub-net address 
and default gateway correct?
NO
Check the connecting cable and LAN settings. If the LAN 
settings are unknown, contact the network administrator. 
If the network settings cannot be saved, replace IC8003 
(EEP ROM) as it may be defective.
YES
Note: When IC8003 (EEP ROM) is replaced, the MAC 
address returns to default. Refer to "Resetting after replac-
ing IC8003 (EEP ROM)" to reset.
Are the network device (e.g. Hub) between 
the control PC and XG-MB67X and cable 
normal?
NO
Repair defective parts in the network.
YES
When data is sent from the control PC, do 
pins (30) and (31) of IC8201 (PHY receiver) 
receive signals?
NO
Check the peripheral circuit of J8201 (RJ-45 jack with built-
in transformer).
YES
Check the PHY receiver IC8201 and the 
peripheral circuits of the microprocessor 
IC8001.
Page of 11
Display