XG-MB67X (serv.man3). Troubleshooting Table - Sharp Projector Service Manual (repair manual). Page 8

Read Sharp XG-MB67X (serv.man3) Service Manual online

XG-MB67X
8 – 8
Check when the lamp turns 
off soon after turning on
Have connectors P1703, 
P1721, P1722, P1723 and 
P1724 come off or are they 
loose?
YES
Securely insert the connec-
tors.
NO
Is each cooling fan rotating?
NO
Check the cooling fan.
YES
Is approx. 3 V applied to 
TL1721?
NO
Check peripheral circuits of 
Q1721.
YES
Is 12 V applied to TL1761?
NO
Check IC1761, IC3581 and 
peripheral circuits.
Go to "DMD system check".
YES
Is 2.5 V applied to TL1763?
NO
Is 3.3 V applied to TL1762? YES
Check IC1762 and peripheral cir-
cuits.
YES
NO
Check IC1763 and periph-
eral circuits.
Is 5 V applied to TL1791?
NO
Check IC1791 and periph-
eral circuits.
YES
Is 5 V applied to TL1712?
NO
Is 5 V applied to TL1712 
with P1703 removed?
NO
Check connection of FB1710.
YES
YES
Is the signal of 180 Hz sent to 
TL1716? (When vertical fre-
quency of the input signal is 
60 Hz)
NO
Check PHOTO SENSOR 
PWB.
YES
Is the signal of 180 Hz sent to 
TL1706? (When vertical fre-
quency of the input signal is 
60 Hz)
NO
Check IC1701 and periph-
eral circuits.
YES
Check the power PWB.