Completing installation and starting up
To finish the installation of the Fiery Server at the customer site, make sure to do 
the following:
1 Make sure that the MFP is powered on.
2 Power on the Fiery Server (see 
page 26
).
Make sure that the power cord is attached and that the power switch on the connector panel is 
in the ON position. Press the power button on the front panel once and release the button. 
The power supply automatically senses the correct voltage.
3 Perform any required system software upgrades.
For instructions, see the documentation that accompanies the Fiery Server service upgrade.
Updates to Fiery Server Software may be available for the Fiery Server from a variety of 
sources (for example, System Updates (see 
page 86
), patches provided on CD, or patches 
downloaded by the customer). 
Windows operating system updates should be obtained from Microsoft directly. Because such 
updates are available directly from Microsoft, EFI does not maintain or provide them via the 
System Updates feature.
4 Print a Test Page and a Configuration page and ask the customer to verify the output. 
5 If the Fiery Server requires a static IP address (for example, in a non-DHCP network 
environment), work with the network administrator to configure it as described on 
page 21
.
6 Change the factory default language, if needed.
For more information on changing the factory default language, see 
page 83
.
7 Ask the network administrator to perform Setup and to print some test documents over 
the network.
8 Store the output and the current Configuration page(s) near the MFP.
9 Inform the site administrator that the Fiery Server user software must be installed on 
networked computers that print to the Fiery Server. 
10 Ask the site administrator to make sure that all media (DVDs and/or CDs) shipped with the 
Fiery Server is stored in a safe location, accessible to you.