Sharp Electronics (UK) Ltd., Technical Services Group
 
 
 
 
 
 
  - How to mount Plygon motor 
 
    1. Pleace the polygon motor on top of the polygon plate. 
 
 
 
 
 
 
 
     
 
 
2. Place the polygon motor on the polygon plate in the LSU case and tighten them with screws 
 
 
 
 
      Note: Tighten them with screws in the following order: 
 
 
 
 
 
 
 
 
 
 
 
3. Action: 
 
From November 2011 production 
4. Parts Action: 
 
Ref. 
No. 
Model 
name 
Version  P/G No. 
Current parts 
New parts 
Price 
rank 
Q'ty 
Parts name 
Effective 
time 
Inter- 
change
ability 
Parts code 
Parts code 
MX-M850 
MX-M950 
MX-M1100 
Except 
for 
Taiwan 
33-1 
RMOTP0961FCPZ 
RMOTP1023FCPZ 
BS 
Polygon motor 
2011/11 
33- 
LPLTM8256FCZZ 
AH 
Polygon plate 
33- 
XBBS730P03000 
AA 
Screw(M3x3) 
33- 
DHAI-4047FCPZ 
DHAI-5113FCPZ 
BM 
PGM harness 
MX-M850 
33-5 
DUNT-7905DSZZ 
DUNT-7905DS16 
CY 
LSU 
MX-M950 
DUNT-7905DS11 
DUNT-7905DS17 
MX-M1100 
DUNT-7905DS12 
DUNT-7905DS18 
<Interchange> 
1. Interchangeable. 
4. Not interchangeable. 
2. Current type can be used in place of new type. 
New type cannot be used in place of current type. 
5. Interchangeable if replaced with same types of  
related parts in use. 
3. Current type cannot be used in place of new type. 
New type can be used in place of current type. 
6. Others. 
Parts marked with "
" is important for maintaining the safety of the set. Be sure to replace these parts with 
specified ones for maintaining the safety and performance of the set. 
 
 
 
 1 - 4: Use M3x3 screws (XBBS730P03000) 
 5 - 8: Use M3x8 screws (XBBS730P08000) 
 