MX-M850 (serv.man36). Section 6 Adjustments - Sharp Copying Equipment Service Manual (repair manual). Page 7

Read Sharp MX-M850 (serv.man36) Service Manual online

MX-M1100  ADJUSTMENTS  6 – 7
 
1-F
Photoconductor dark potential adjustment
This adjustment is needed in the following situations:
* When the photoconductor drum is replaced.
* When the front surface potential sensor is replaced.
* When the main charger unit is replaced.
* When the main high voltage PWB is replaced.
* When the photoconductor unit (process unit) is disassembled.
* The PCU PWB has been replaced.
* The EEPROM of the PCU PWB has been replaced.
* Before executing the image adjustment
1)
Enter the Sim.44-3 mode. 
2)
Select the adjustment mode.
• INI DARK VO:
When the OPC drum is replaced, select this mode.
• DARK VO: 
In the other cases, select this mode.
3)
Press [EXECUTE] key.
[EXECUTE] button is highlighted, and the OPC drum is rotated
to start the OPC drum dark potential adjustment operation.
After completion of the adjustment, [EXECUTE] button returns
to the normal display.
The main charger grid voltage is automatically corrected until
the OPC drum dark potential becomes the specified value.
 
ADJ 2
Developing unit adjustment
 
2-A
Developing doctor gap adjustment
The check and the adjustment are required in the following cases:
* When the developing unit is disassembled.
* When the print image density is too low.
* When there is a thin spot on a print image.
* When the print image density is uneven.
* When there is abnormally much toner dispersion.
1)
Remove the developing unit from the machine, and remove
the cover and the guide as shown in the figure below.
0
SIMULATION NO.44̆03
TEST
DARK POTENTIAL ADJUSTMENT
EXECUTE
INI TUM AREA
8
:
INI HUM AREA
7
VGL K
LIFE COUNTER
0
:
TARGET VO
650
:
1/1
CLOSE
VO RESULT
650
:
INI DARK VO
DARK VO
GRID BIAS
750
:
INI VG1
0
:
INI VG2
0
:
VG ENV
0
:
VG LIFE
0
:
LIFE K
1
:
1
:
VGH K
1
:
LOW VO
 
0
:
HIGH VO
0
:
Page of 82