MX-M850 (serv.man36). Section 6 Adjustments - Sharp Copying Equipment Service Manual (repair manual). Page 3

Read Sharp MX-M850 (serv.man36) Service Manual online

MX-M1100  ADJUSTMENTS  6 – 3
3. Datails of adjustment
 
ADJ 1
High voltage values adjustment
(Note)
To check and adjust the output voltage, use the unit which can
measure an effective value of 1000M
Ω or more internal imped-
ance.  In addition, use a high voltage probe as well. 
(FLUKE87FLUKE80K-40 is recommended.) 
 
1-A
Main charger grid voltage adjustment
This adjustment is needed in the following situations:
* When the high voltage MAIN PWB is replaced.
* U2 trouble has occurred.
* The PCU PWB has been replaced.
* The EEPROM of the PCU PWB has been replaced.
1)
Enter the Sim. 8-2 mode.
2)
Select the output mode to be adjusted with the scroll button.
3)
Enter the adjustment value with 10-key, and press [OK] button.
The adjustment value is set.
Normally when the default value is set, the specified voltage is
outputted.
When [EXECUTE] button is pressed, the adjustment value is saved
and the main charger voltage is outputted.
When the output voltage must be checked or adjusted, follow the
procedure below:
1)
Remove the upper rear cover of the machine
2)
Attach the digital multi-meter between the connector CN2 pin
(3) on the high voltage main PWB and GND.
3)
Enter the adjustment value with 10-key, and press [EXECUTE]
key.
The main charger voltage is outputted for 10sec.
Note:
Perform this procedure timely as extended charge output will
stress the photoconductor.
A㧦580
COPY
B㧦580
PRINTER
C㧦580
FAX
0
A:
SIMULATION NO.08㧙02
MHV/GRID SETTING AND OUTPUT
580
200 㨪1000 㨉
OK
TEST
EXECUTE
CLOSE
Item/Display
Content
Setting 
range
Default
Monitor connector
Actual output voltage
85-sheet 
model
95/110-
sheet model
Connector
Pin No.
85-sheet 
model
95/110-sheet 
model
A
COPY
Main charger grid voltage adjustment value 
(Copy mode)
200-1000
560
580
CN2
3
-590 
± 1 V
-610 
± 1 V
B
PRINTER
Main charger grid voltage adjustment value 
(Priner mode)
200-1000
560
580
CN2
3
-590 
± 1 V
-610 
± 1 V
C
FAX
Main charger grid voltage adjustment value 
(FAX mode)
200-1000
560
580
CN2
3
-590 
± 1 V
-610 
± 1 V
CN2
Page of 82