Read Sharp MX-M850 (serv.man36) Service Manual online
MX-M1100 ADJUSTMENTS 6 – 11
5)
Open the front cabinet. Remove the toner bottle unit.
6)
Remove the the process cover.
7)
Loosen the fixing screw of the print image distortion adjust-
ment cam. Adjust the angle of the print image distortion adjust-
ment cam to set the print image distortion to the minimum.
ment cam. Adjust the angle of the print image distortion adjust-
ment cam to set the print image distortion to the minimum.
When the vertical line image is tilted to the left with the front
frame side as the reference, turn the print image distortion
adjustment cam clockwise to change the angle.
When the vertical line image is tilted to the right with the front
frame side as the reference, turn the print image distortion
adjustment cam counterclockwise to change the angle.
Repeat steps 3 to 7 until an acceptable result is obtained.
frame side as the reference, turn the print image distortion
adjustment cam clockwise to change the angle.
When the vertical line image is tilted to the right with the front
frame side as the reference, turn the print image distortion
adjustment cam counterclockwise to change the angle.
Repeat steps 3 to 7 until an acceptable result is obtained.
3-B
Print engine image magnification ratio
adjustment (Main scanning direction)
adjustment (Main scanning direction)
This adjustment is needed in the following situations:
* LSU (write) unit has been replaced.
* U2 trouble has occurred.
* The PCU PWB has been replaced.
* The EEPROM of the PCU PWB has been replaced.
1)
* LSU (write) unit has been replaced.
* U2 trouble has occurred.
* The PCU PWB has been replaced.
* The EEPROM of the PCU PWB has been replaced.
1)
Enter the Sim.50-10 mode.
2)
Select A4 (11
✕ 8.5) paper.
3)
Press [EXECUTE] key.
The check pattern is printed out.
The check pattern is printed out.
4)
Check that the inside dimension of the printed half tone is 240
± 0.5mm.
± 0.5mm.
If the above requirement is not met, do the following steps.
5)
Change the set value of set item A.
When the set value is changed by 1, the dimension is changed
by 0.1mm.
When the set value is increased, the main scanning direction
image magnification ratio in the main scanning direction is
increased. When the set value is decreased, the mian scan-
ning direction image magnification ratio in the main scanning
direction is decreased.
Repeat procedures 3 thru 5 until a satisfactory result is
obtained.
When the set value is changed by 1, the dimension is changed
by 0.1mm.
When the set value is increased, the main scanning direction
image magnification ratio in the main scanning direction is
increased. When the set value is decreased, the mian scan-
ning direction image magnification ratio in the main scanning
direction is decreased.
Repeat procedures 3 thru 5 until a satisfactory result is
obtained.
A㧦100
㧧
BK-MAG
B㧦 50
㧧
CS1
C㧦 50
㧧
CS2
D㧦 50
㧧
CS3
0
A:
SIMULATION NO.50㧙10
PAPER CENTER OFFSET SETUP
100
㨇
60㨪 140 㨉
OK
TEST
CLOSE
E㧦 50
㧧
CS4
F㧦 50
㧧
ADU
G㧦 50
㧧
MFT
H㧦 50
㧧
LCC
I㧦 1
㧧
MULTICOUNT
J㧦 2
㧧
PAPER㧦CS1
K㧦 1
㧧
DUPLEX㧦NO
EXECUTE
Click on the first or last page to see other MX-M850 (serv.man36) service manuals if exist.