Read Sharp MX-M850 (serv.man15) Service Manual online
MX-M1100 SCANNER SECTION D – 7
d. SCN-Mother PWB
1)
Open the DSPF unit (a).
2)
Remove the screw (a). Remove the table glass holder (b) and
the table glass (c).
the table glass (c).
3)
Disconnect the connector (a). Remove the screw (b), and pull
out the SCNCNT PWB mounting plate (c).
out the SCNCNT PWB mounting plate (c).
4)
Remove the screw (a), and remove the plate (b).
5)
Remove the screw (a), and disconnect the connector (b).
Remove the SCN-Mother PWB (c).
Remove the SCN-Mother PWB (c).
e. SCN-Flash PWB / SCNCNT PWB
1)
Remove the upper cabinet left.
2)
Push the lock (a) to release, and remove the SCN-Flash PWB
(b).
(b).