Read Sharp MX-M850 (serv.man15) Service Manual online
MX-M1100 SCANNER SECTION D – 5
c)
Check to confirm that the harness (a) is shifted by 4mm
when released, and fix it with the harness holder (b).
Install the connector (c).
Check that the harness is not twisted.
when released, and fix it with the harness holder (b).
Install the connector (c).
Check that the harness is not twisted.
b. Sub scanning document size sensor / Main scanning
document size sensor
1)
Open the DSPF unit (a).
2)
Remove the screw (a). Remove the table glass holder (b) and
the table glass (c).
the table glass (c).
3)
Remove the screw (a), and remove the dark box cover (b).
4)
Remove the screw (a), and remove the sub scanning docu-
ment size sensor (b).
ment size sensor (b).
5)
Remove the screw (a), and remove the plate (b).
6)
Remove the screw (a), and remove the main scanning docu-
ment size sensor (b).
ment size sensor (b).
4mm
a
b
c
a
a
b
c
a
a
b
b
a
a
b
a
b
a
a
b
b