Read Sharp MX-M850 (serv.man15) Service Manual online
MX-M1100 SCANNER SECTION D – 6
c. CL inverter PWB / AFE PWB / CCD cooling fan / CCD unit
1)
Open the DSPF unit (a).
2)
Remove the screw (a). Remove the table glass holder (b) and
the table glass (c).
the table glass (c).
3)
Remove the screw (a), and remove the dark box cover (b).
4)
Disconnect the connector (a) and remove the screw (b). Disen-
gage the spacer lock (c), and remove the CL inverter PWB (d).
gage the spacer lock (c), and remove the CL inverter PWB (d).
5)
Remove the screw (a), and disconnect the connector (b).
Remove the AFE PWB (c).
Remove the AFE PWB (c).
6)
Disconnect the connector (a), and Remove the screw (b).
Remove the plate (c). Remove the screw (d), and remove the
CCD cooling fan (e).
Remove the plate (c). Remove the screw (d), and remove the
CCD cooling fan (e).
7)
Disconnect the connector (a), and remove the screw (b).
Remove the CCD unit (c).
Remove the CCD unit (c).
a
a
b
c
a
a
b
b
d
a
c
a
a
b
b
c
b
a
a
b
a
d
d
e
c
c
b
b
b
b
a
a
Click on the first or last page to see other MX-M850 (serv.man15) service manuals if exist.