MX-M565N  MX-EB12N  25 – 5
Phenomenon 2
The mirroring information has not been deleted normally.
Phenomenon 3
Though the target HDD is connected, it is not displayed.
Cause
Temporary communication trouble, cable or other 
device trouble, HDD trouble
Countermeasures
1. Click [Clear RIB in HDD] button again.
2. If the trouble is not solved by procedure 1. , 
disconnect and connect the cable, change the 
devices, and reboot the RIB Buster. Then execute 
procedure 1.
Cause
The target HDD is not registered in the Setup.ini file. 
Cable or other device trouble, HDD trouble
Countermeasures
1. Reboot RIB Buster. Click the framed section.
2. If the trouble is not solved by procedure 1. , 
replace the Setup. ini file and the RIB Buster 
{YYYYMMDD} with the latest version, and execute 
procedure 1. .
3. If the trouble is not solved by procedure 2. , 
disconnect and connect the connector, change the 
devices, and reboot the RIB Buster. Then execute 
procedure 1. .