MX-M182 DISASSEMBLY AND ASSEMBLY 10-15
11.Developing section
A. Developing box
B. Developing doctor
Adjustment:
Developing doctor gap adjustment
C. MG roller
Adjustment:
MG roller main pole position adjustment
Note:Attach it to fit with the attachment reference when replacing the DV
blade.
No.
Contents
A
Developing box
B
Developing doctor
C
MG roller
(2)
(3)
(3)
(3)
(4)
(1)
(1)
(2)
(5)
(4)
(3)
(3)
0
0.5
0
0.5
Attaching
reference
reference
DV blade
Mark-off line
Mark-off line
reference
reference
The DV blade surface must be free
from foreign materials.
from foreign materials.
Do not touch the DV blade tip.
It must be free from deflection.
It must be free from deflection.