MX-M182, MX-M182D (serv.man5). Service Manual December 2011. - Sharp Copying Equipment Service Manual (repair manual). Page 127

Read Sharp MX-M182 / MX-M182D (serv.man5) Service Manual online

MX-M182 FLASH ROM VERSION UP PROCEDURE 12-1
[12] FLASH ROM VERSION UP PROCEDURE
1. Preparation
Write the download data (the file with the extension dwl) to the main 
body.
Necessary files for download
• Maintenance.exe (Maintenance software) 
• ProcModelH.mdl.SE
• ProcModelH.ini.SE
• ProcModelH.fmt.SE
• SFAXNoXXX.fld
• Mainte.inf
• Usbscan.sys
• Download file:***.dwl
<Note>
•The Download file(***.dwl ) and the like that are to be downloaded 
should be copied, in advance, into folders that have a maintenance 
program.
•When creating a folder for a maintenance tool in the PC, be sure that no 
lengthy folder name is included in the path.
(Example)
Incorrect  c:\Maintenance Download Tool
Correct    c:\Maintenance\Downtool
2. Download procedure
1) Main body side: 
Executable by performing the Service Simulation No. 49-01 (Flash 
Rom program-writing mode).
(A word "Download mode." appears on the operation panel to denote 
the download mode status. )
2) Connect the PC and the main body with the download cable 
(USB cable).
3) PC side:
Boot the maintenance program. Select the model icon.
<Sample display>
4) PC side: 
Confirm that the "Simulation Command List" tree is displayed on the 
maintenance program.
5) PC side:
When the message "the copier is off" is displayed on the lowest area 
of the figure below after the "maintenance program" is started up, 
select the "File" and then "Reconnect" in the menu bar.
6) PC side:
Confirm a tree is displayed under the "Special (MCU/Panel/
Facsimile)" on the maintenance program". (If no tree is displayed, 
confirm that the USB is connected and select the "Reconnect" (the 
above 5) again.)
Page of 127