MX-M1205  MX-M1055/M1205 (MAIN UNIT)  2 – 17
17) Insert the toner tray (a), and close the front cover (b). 
G. Toner collection container check
1) Open the front cover (a).
2) Check to confirm that toner collection container (a) is securely
installed. 
H. Toner density reference control level setting
1)
Connect the power cord of the main unit to the power 
outlet.
2)
Open the front cover, and turn ON the main power switch.
3)
Turn ON the power switch on the operation panel. 
4)
Open  the  front  cover,  and  remove  the  toner  cartridge.  Then
enter the input of SIM25-2.
5)
After entering the simulation, close the front cover (a).
6)
Press [EXECUTE] button, and the simulation is executed. 
After stirring toner, the toner density control sensor values are
sampled to get the average value of the sensor detection level,
which  is  set  (saved)  as  the  reference  toner  density  control
value. 
7)
After completion of the reference toner density control value 
setting, [EXECUTE] key returns to the normal display, showing
completion of the setting operation.
I. Toner cartridge installation
1)
Pull out the toner tray (a).
b
a
a
a
a