MX-FNX6. Service Manual 01.05.08 - Sharp Copying Equipment Service Manual (repair manual). Page 27

Read Sharp MX-FNX6 Service Manual online

MX-FNX6  REPLACEMENT AND ADJUSTMENT  4 – 9
6)
Fit the rank seal on the back of the new folding unit, and set
the DIP switch of the main PWB again.
<Center folding stapler replacement and adjustment 
(MX-FNX7 only)>
* If there is a horizontal shift or a vertical shift in center folding,
perform the center folding shift adjustment in advance.
7)
Remove the guide plate.
8)
Remove the stay. (4 screws)
9)
Remove the plate. (4 screws)
Disassembly
10) Remove the cover (2 screws)
11) Remove the bracket. (Connector 2 positions, 4 screws)
12) Remove the stapler: upper from the bracket. 
(4 screws for each)
13) Remove the stapler: lower. 
(Connector 1 position for each, 2 screws)
Replacement and adjustment
14) Install a new stapler: upper to the bracket (4 screws for each),
and set the jig included in the package to the back side. 
15) Install the bracket. (Connector 2 positions, 4 screws)
16) Install the new stapler: lower, and fix it temporarily. 
(Connector 1 position for each, 4 screws)
17) Turn the staple motor gear with fingers to extend the stapler
hammer to the maximum.
18) With the staple hammer stored in the jig hole and the stapler:
upper pushed in, tighten two fixing screws of the stapler: lower.
Main PWB DIP switch
Rank seal on the back
of the folding unit
Guide plate
Stay
Plate
Cover
Cover
Page of 36
Display

Click on the first or last page to see other MX-FNX6 service manuals if exist.