MX-FN19, MX-FN20, MX-PN12. All Sections - Sharp Copying Equipment Specification (repair manual). Page 25

Read Sharp MX-FN19 / MX-FN20 / MX-PN12 Specification online

MX-FN19  MAINTENANCE  4 – 8
CAUTION: When installing, be sure to engage the two pawls [4] of
the left upper cover with the metal plates.
g. Removal of grate-shaped upper guide
1) Move the tray [1] lower than the grate-shaped upper guide [2].
(For moving of the tray, refer to "Removal of No. 1 tray")
2) Remove the five screws [3], and remove the grate-shaped
upper guide [2].
h. Removal of No. 1 tray
CAUTION: Note for installing or moving the tray
When moving down the tray, push up the shutter [1],
and release the latch [2] on the lower surface of the tray
to lower the tray.
When the latch is released, the tray will free-fall. Hold
the tray with your hand during the removal.
1)
Remove the screw [1], and remove the metal plate [2] and the
slide guide [3]. If the grate-shaped upper guide is removed,
this procedure is unnecessary.
2)
Remove the screw [4], and remove the stopper [5].
[4]
[3]
[2]
[1]
[2]
[1]
[1]
[3]
[2]
[5]
[4]