MX-C300P  MAINTENANCE  9 – 4
3.Maintenance list
✕: Check (Clean, replace, or adjust according to necessity.) O: Clean S: Replace U: Adjust ✩: Lubricate
MX-CS11
Section name
Unit name
When 
calling
45
K
75
K
90
K
135 
K
150
K
180
K
225 
K
270
K
300
K
Remarks
OPC drum section
OPC drum unit (mono-
chrome)
 - 
 - 
S
 - 
 - 
S
 - 
S
 - 
S
OPC drum unit (color)
 - 
S
 - 
S
S
 - 
S
S
S
 - 
Developing section
Developing unit (mono-
chrome)
 - 
 - 
S
 - 
 - 
S
 - 
S
 - 
S
Developing unit (color)
 - 
S
 - 
S
S
 - 
S
S
S
 - 
Toner cartridge
Toner cartridge BK
User replacement for every toner empty.
Toner cartridge CMY
User replacement for every toner empty.
Toner collection 
container
Toner collection con-
tainer
Replaced by the user when full is detected.
Section 
name
Unit name
Part name
When
calling
75
K
150
K
225
K
300
K
Remark
Transfer 
section
Primary
transfer unit
Primary transfer unit
X
 
S
 - 
S
Replace at 150K or 2 year of use.
Secondary 
transfer unit
Secondary transfer roller
X
 
O
 
O
Replace as needed
LSU section LSU
Dust-proof glass
X
X
X
X
X
Others
LSU cleaning unit
X
S
S
S
S
Replace as needed
Paper feed 
section
Manual
paper feed 
unit/Tray 
paper feed 
unit
Paper feed roller
X
O
O
O
O
Replace at 100K of each counter or 1 year 
of use. 
Separation roller
X
O
O
O
O
Torque limiter
X
O
O
O
O
Sensors
X
X
X
X
X
Paper regis-
tration
section 
(paper
transport 
section)/
Paper exit 
section/
ADU
section
PS auxilrary roller
X
O
O
O
O
Transport rollers
X
O
O
O
O
Paper guides
O
O
O
O
O
Discharge brush
X
X
X
X
X
Gears
X
X
X
X
X
Apply to the specified area when checking. 
FLOIL GE-676
Paper dust removing unit
Drive sec-
tion
Gears (grease)
X
X
X
X
X
Apply to the specified area when checking. 
FLOIL G-313S
Shaft earth sections
conduction grease
X
X
X
X
X
Apply to the specified area when checking. 
FLOIL GE-676
Belts
X
X
X
X
X
Sensors
X
X
X
X
X
Fusing sec-
tion
Fusing unit
Fusing unit
X
 
S
 - 
S
Replace at 150K or 2 year of use.
Other
Process registration sensor 
X
O
O
O
O
Clean when the Fusing unit and the Drum 
cartridge is replaced.  
Ozone filter
X
S
S
S
S
Replace at 75K  
Section 
name
Unit 
name
Part name
When
calling
75 K
150 K
225K
300 K
Remark
MX-CS11
Pick-up roller
O
O
O
O
O
When the paper feed counter reaches a value 
of 100K or when one year has elapsed since 
the start of use.
Paper feed roller
O
O
O
O
O
Separation roller
O
O
O
O
O
Torque limiter
X
X
X
X
X
Transport rollers
X
O
O
O
O
Transport paper guides
O
O
O
O
O
Discharge brush
X
X
X
X
X
Gears
X
X
X
X
X
Apply to the specified area when checking. 
FLOIL GE-676