Read Sharp MX-C300P / MX-C300PE / MX-C300PL Service Manual online
MX-C300P MAINTENANCE 9 – 4
3.Maintenance list
✕: Check (Clean, replace, or adjust according to necessity.) O: Clean S: Replace U: Adjust ✩: Lubricate
MX-CS11
Section name
Unit name
When
calling
45
K
75
K
90
K
135
K
150
K
180
K
225
K
270
K
300
K
Remarks
OPC drum section
OPC drum unit (mono-
chrome)
chrome)
-
-
S
-
-
S
-
S
-
S
OPC drum unit (color)
-
S
-
S
S
-
S
S
S
-
Developing section
Developing unit (mono-
chrome)
chrome)
-
-
S
-
-
S
-
S
-
S
Developing unit (color)
-
S
-
S
S
-
S
S
S
-
Toner cartridge
Toner cartridge BK
User replacement for every toner empty.
Toner cartridge CMY
User replacement for every toner empty.
Toner collection
container
container
Toner collection con-
tainer
tainer
Replaced by the user when full is detected.
Section
name
Unit name
Part name
When
calling
75
K
150
K
225
K
300
K
Remark
Transfer
section
section
Primary
transfer unit
transfer unit
Primary transfer unit
X
-
S
-
S
Replace at 150K or 2 year of use.
Secondary
transfer unit
transfer unit
Secondary transfer roller
X
-
O
-
O
Replace as needed
LSU section LSU
Dust-proof glass
X
X
X
X
X
Others
LSU cleaning unit
X
S
S
S
S
Replace as needed
Paper feed
section
section
Manual
paper feed
unit/Tray
paper feed
unit
paper feed
unit/Tray
paper feed
unit
Paper feed roller
X
O
O
O
O
Replace at 100K of each counter or 1 year
of use.
of use.
Separation roller
X
O
O
O
O
Torque limiter
X
O
O
O
O
Sensors
X
X
X
X
X
Paper regis-
tration
section
(paper
transport
section)/
Paper exit
section/
ADU
section
tration
section
(paper
transport
section)/
Paper exit
section/
ADU
section
PS auxilrary roller
X
O
O
O
O
Transport rollers
X
O
O
O
O
Paper guides
O
O
O
O
O
Discharge brush
X
X
X
X
X
Gears
X
X
X
X
X
Apply to the specified area when checking.
FLOIL GE-676
FLOIL GE-676
Paper dust removing unit
Drive sec-
tion
tion
Gears (grease)
X
X
X
X
X
Apply to the specified area when checking.
FLOIL G-313S
FLOIL G-313S
Shaft earth sections
conduction grease
conduction grease
X
X
X
X
X
Apply to the specified area when checking.
FLOIL GE-676
FLOIL GE-676
Belts
X
X
X
X
X
Sensors
X
X
X
X
X
Fusing sec-
tion
tion
Fusing unit
Fusing unit
X
-
S
-
S
Replace at 150K or 2 year of use.
Other
Process registration sensor
X
O
O
O
O
Clean when the Fusing unit and the Drum
cartridge is replaced.
cartridge is replaced.
Ozone filter
X
S
S
S
S
Replace at 75K
Section
name
Unit
name
Part name
When
calling
75 K
150 K
225K
300 K
Remark
MX-CS11
Pick-up roller
O
O
O
O
O
When the paper feed counter reaches a value
of 100K or when one year has elapsed since
the start of use.
of 100K or when one year has elapsed since
the start of use.
Paper feed roller
O
O
O
O
O
Separation roller
O
O
O
O
O
Torque limiter
X
X
X
X
X
Transport rollers
X
O
O
O
O
Transport paper guides
O
O
O
O
O
Discharge brush
X
X
X
X
X
Gears
X
X
X
X
X
Apply to the specified area when checking.
FLOIL GE-676
FLOIL GE-676
Click on the first or last page to see other MX-C300P / MX-C300PE / MX-C300PL service manuals if exist.