MX-B201/B201D SIMULATION, TROUBLE CODES 10 - 44
:'11/Oct/17
1
F2
74
Content Toner cartridge CRUM error
Detail
Detail
MCU
Cause
Toner cartridge (CRUM) trouble.
MCU PWB trouble.
Connector/harness trouble.
MCU PWB trouble.
Connector/harness trouble.
Check
and
remedy
and
remedy
Replace the toner cartridge.
Replace the MCU PWB.
Connector and harness check.
Replace the MCU PWB.
Connector and harness check.
F5
02
Content Copy lamp lighting abnormality
Detail
Detail
The copy lamp does not turn on.
Cause
Copy lamp abnormality
Copy lamp harness abnormality
CCD PWB harness abnormality.
Copy lamp harness abnormality
CCD PWB harness abnormality.
Check
and
remedy
and
remedy
Use SIM 5-3 to check the copy lamp
operations.
When the copy lamp lights up.
Check the harness and the connector
between the CCD unit and the MCU PWB.
When the copy lamp does not light up.
Check the harness and the connector
between the copy lamp unit and the MCU
PWB.
Replace the copy lamp unit.
Replace the MCU PWB.
operations.
When the copy lamp lights up.
Check the harness and the connector
between the CCD unit and the MCU PWB.
When the copy lamp does not light up.
Check the harness and the connector
between the copy lamp unit and the MCU
PWB.
Replace the copy lamp unit.
Replace the MCU PWB.
F6
60
Content AFAX plug detect error
Detail
Detail
For USB connection with AFAX, ANB cannot
detect the connection with AFAX.
detect the connection with AFAX.
Cause
USB connected error between ANB and
AFAX
AFAX
Check
and
remedy
and
remedy
Replace the ANB PWB or AFAX PWB.
90
Content AFAX USB communicate error
Detail
Detail
For interface, ANB cannot be communicated
with AFAX.
with AFAX.
Cause
Interface error between ANB and AFAX
Check
and
remedy
and
remedy
Check the connection between ANB and
AFAX.
Replace the ANB PWB or AFAX PWB.
AFAX.
Replace the ANB PWB or AFAX PWB.
92
Content ANB flash error
Detail
Can not read /write to Flash ROM on the
ANB PWB.
ANB PWB.
Cause
Access error to Flash ROM.
Check
and
remedy
and
remedy
Replace the ANB PWB.
94
Content AFAX register error
Detail
Can not access to MODEM on the AFAX
PWB.
PWB.
Cause
Access error to MODEM
Check
and
remedy
and
remedy
Replace AFAX PWB.
H2
00
Content Thermistor open
Detail
Detail
The thermistor is open.
The fusing unit is not installed.
The fusing unit is not installed.
Cause
Thermistor abnormality
Control PWB abnormality
Fusing section connector disconnection
The fusing unit is not installed.
Control PWB abnormality
Fusing section connector disconnection
The fusing unit is not installed.
Check
and
remedy
and
remedy
Check the harness and the connector
between the thermistor and the PWB.
Use SIM 14 to clear the self diagnostic
display.
between the thermistor and the PWB.
Use SIM 14 to clear the self diagnostic
display.
Main
code
code
Sub
code
Details of trouble
1
H3
00
Content Heat roller high temperature detection
Detail
Detail
The fusing temperature exceeds 240°C.
Cause
Thermistor abnormality
Control PWB abnormality
Fusing section connector disconnection.
Control PWB abnormality
Fusing section connector disconnection.
Check
and
remedy
and
remedy
Use SIM 5-02 to check the heater lamp
blinking operation.
When the lamp blinks normally.
Check the thermistor and its harness.
Check the thermistor input circuit on the
control PWB.
When the lamp keeps ON.
Check the power PWB and the lamp control
circuit on the MCU PWB.
Use SIM 14 to clear the self diagnostic
display.
blinking operation.
When the lamp blinks normally.
Check the thermistor and its harness.
Check the thermistor input circuit on the
control PWB.
When the lamp keeps ON.
Check the power PWB and the lamp control
circuit on the MCU PWB.
Use SIM 14 to clear the self diagnostic
display.
H4
00
Content Heat roller low temperature detection
Detail
Detail
1) When the target temperature (165°C) is
not reached in 55 sec after starting
warming-up.
warming-up.
2) When the temperature below 100°C is
detected for 300ms under the ready print
state.
state.
∗ "Starting warming-up" means not only that
in power supply but also reset that in reset
from shut-off and in side door close. (The
timing of generating H4 is not limited to
that in power supply.)
from shut-off and in side door close. (The
timing of generating H4 is not limited to
that in power supply.)
Cause
Thermistor abnormality
Heater lamp abnormality
Thermostat abnormality
Control PWB abnormality
Heater lamp abnormality
Thermostat abnormality
Control PWB abnormality
Check
and
remedy
and
remedy
Use SIM 5-02 to check the heater lamp
blinking operation.
When the lamp blinks normally.
Check the thermistor and its harness.
Check the thermistor input circuit on the
control PWB.
When the lamp does not light up.
Check for disconnection of the heater lamp
and the thermostat. Check the interlock
switch.
Check the power PWB and the lamp control
circuit on the MCU PWB.
Use SIM 14 to clear the self diagnostic
display.
blinking operation.
When the lamp blinks normally.
Check the thermistor and its harness.
Check the thermistor input circuit on the
control PWB.
When the lamp does not light up.
Check for disconnection of the heater lamp
and the thermostat. Check the interlock
switch.
Check the power PWB and the lamp control
circuit on the MCU PWB.
Use SIM 14 to clear the self diagnostic
display.
Main
code
code
Sub
code
Details of trouble
Click on the first or last page to see other MX-B201D (serv.man9) service manuals if exist.