MX-B201D (serv.man9). Service Manual (October 2011). - Sharp Copying Equipment Service Manual (repair manual). Page 115

Read Sharp MX-B201D (serv.man9) Service Manual online

MX-B201/B201D  SIMULATION, TROUBLE CODES  10 - 40
:'11/Oct/17
1
66
13
Dial test 
(When MX-FX12 is installed)
[Function]
Use to the dial test.
[Operation]
17
DTMF signal send 
(Max. value) 
(When MX-FX12 is installed)
[Function]
Use to set the DTMF signal send (Max. value).
[Operation]
Main 
code
Sub 
code
Contents
Details of function/operation
1
■ Dial test (PULSE)
1) Initial display
* [Clear] key: FAX control is termi-
nated.
2) Select 1
3) Enter the make time in 2 digits.
* After deleting with [Clear] key, input
can be made.
4) [OK] key
"yy" is the selected pulse 10 or 20.
"xx" is the input value.
* Select 2: Returns to “2)” display.
5) Select 1
Switched to 10/20PPS set with
pulse selection inside.
6) After setting
7) After completion of sending
* Select 2: Returns to “4)” display.
8) Select 1
After 2sec, returns to "1) Initial display".
SELECT SIGNAL
1:PULSE    2:DTMF
INPUT MAKE TIME
(0-15)            __
INPUT DIAL #
SEND yyPPS xxms
1:YES 2:NO
SENDING yyPPS xxms
TERMINATE ?
1:YES 2:NO
TERMINATED
■ Dial test (DTMF)
1) Initial display
* [Clear] key: FAX control is terminated.
2)
Select 2
↓ Select 2
3)
Select 1
↓ Select 2
4) Select 1
* After deleting with [Clear] key, input can be
made.
4) [OK] key
"xx" indicates HI, and "yy" indicates Low Soft SW.
* Select 2: Returns to “4)” display.
5) Select 1
HI/LO is selected with the signal level inside.
6) After setting the signal send level
7) After completion of sending
* Select 2: Returns to “4)” display.
8) Select 1
After 2sec, returns to "1) Initial display".
SELECT SIGNAL
1:PULSE    2:DTMF
SELECT HIGH LEVEL
1:DEFAULT 2:SOFT SW.
INPUT VALUE
(0-15)            __
SELECT LOW LEVEL
1:DEFAULT 2:SOFT SW.
INPUT VALUE
(0-15)            __
INPUT DIAL #
H:xx        L:yy
1:YES 2:NO
SENDING DTMF
TERMINATE ?
1:YES 2:NO
TERMINATED
1) Initial display
* [Clear] key: FAX control is terminated.
2) [Numeric] key: Input
The content selected with signal send
level selection is set inside.
3) Communication is started after setting the
signal send level.
* [Clear] key: Returns to "1) Initial display".
INPUT DIAL #
SENDING SIGNAL MAX
PRESS CLEAR TO STOP
Page of 127
Display