MX-FX12  FAX SOFT SWITCH  2 - 11
S
W
37
1
Inhibited to use
0
2
0
3
0
4
0
5
0
6
0
7
0
8
0
S
W
38
1
Protocol monitor
Used to set whether communication protocol result is printed or not 
after completion of communication.
Not output
0
Bit No.
1
2
2
Not output
0
0
0
Not output
0
1
Output
1
0
Output only in an error
1
1
3
Protocol monitor 
save
Used to set whether the protocol monitor of the last communication 
is saved or not. When set to “Saved,” the previous protocol monitor 
can be printed with SIM66-21.
Yes
1
1: Yes
0: No
4
Inhibited to use
0
5
Flash send time 
(U.S.A., Canada, 
U.K., Netherlands, 
Luxembourg, 
Belgium, France, 
Australia, New 
Zealand: Inhibited 
to use)
Used to set the Flash send time.
90ms
0
Bit No.
5
6
90ms
0
0
6
180ms
0
1
0
270ms
1
0
360ms
1
1
7
Transfer function
Used to set whether transfer function is enabled or not.
Allow
1
1: Allow
0: Inhibit
8
Inhibited to use
0
S
W
39
1
Threshold of 
electric current in 
fax starting
Setting of amount of current of line that machine detects at auto 
dialing. When it is fewer than this value, the machine is not sent.
>= 12mA 
(LVCS:1)
0
2
Bit  No.
1
2
3
0
Current is disregarded.
0
0
0
>= 12mA (LVCS:1)
0
0
1
3
>= 15mA (LVCS:2)
0
1
0
1
>= 18mA (LVCS:3)
0
1
1
>= 21mA (LVCS:4)
1
0
0
4
DTMF signal send 
time
Used to set DTMF signal send time.
110ms
0
When a value outside the 
set range is set, the initial 
value is set.
Setting is made in binary input by the increment of 10ms.
5
Binary input
1
Bit No.
Set range
4
5
6
7
8
60 to 310ms 
(North America)
70 to 310ms
(Except North America)
10ms unit
6
0
7
1
8
1
S
W
40
1
Number of times 
of recall in error
Used to set the number of times of recall when a communication 
error occurs.
1 times
0 Refer to User program 
“RECALL TIMES (LINE 
ERROR)”.
When a value outside the 
set range is set, the initial 
value is set.
2
0
3
Setting is made in binary input.
0
4
When set to 0, recall is not made.
0
5
Set range
0
0 to 1 times
(U.S.A., Australia, New Zealand)
0 to 5 times
(U.K., Germany, France, Middle East)
0 to 9 times
(Singapore, Malaysia, India, Indonesia, Thailand, Vietnam)
0 to 3 times
(Hong Kong, China)
6
0
7
0
8
1
SW 
NO.
Data 
No.
Item
Switch selection and contents of functions
Initial value
Remark