MX-B201D (serv.man6). Service Manual MX-FX12 - Sharp Copying Equipment Service Manual (repair manual). Page 15

Read Sharp MX-B201D (serv.man6) Service Manual online

MX-FX12  FAX SOFT SWITCH  2 - 10
S
W
33
1
Page number print 
setup
Used to set whether the page number is added to the sender 
information print or not.
Yes
1
1: Yes
0: No
2
Inhibited to use
0
3
0
4
0
5
0
6
0
7
0
8
Reception data 
duplex print
Used to set whether duplex print of received data is made or not.
No
0
Refer to User program 
“DUPLEX RCV”.
1: Yes
0: No
S
W
34
1
Flash send wait 
time (U.S.A., 
Canada, U.K., 
Netherlands, 
Luxembourg, 
Belgium, France, 
Australia, New 
Zealand: Inhibited 
to use)
Used to set the time from off-hook to Flash send.
1sec.
0
Bit No.
1
2
0sec.
0
0
0.5sec.
0
1
2
1sec.
1
0
0
2sec.
1
1
3
Inhibited to use
0
4
0
5
Signal send level 
Max.
Used to set the max. signal send level.
Binary input
–8dBm
1
6
0
7
Bit  No.
Set range
5
6
7
8
0 (0dBm) to 15 (–15dBm)
0
8
0
S
W
35
1
Cover function 
default setup
Used to set whether cover is added as default or not.
When auto clear is made by pressing [Clear All] key, the machine 
returns to this setting.
No
0
1: Yes
0: No
2
Answering 
machine 
connection
Setting to make them connect telephone that has answering 
machine function as external telephone, and unite answering 
machine function to fax receiver function. 
When an absent function of an external telephone is used, it sets it 
to “ON”. 
The setting simultaneously with the dial-in function is improper.
ON
1
1: ON
0: Off
3
CI delete max. 
OFF time
Used to set the max. wait time between detection of CI signal
pulse (number of times) and detection of the next CI signal
pulse.
If CIK signal pulse is not detected within this time, the number of
calls up to that time is cleared.
5sec.
0
4
Bit  No.
3
4
0
5sec.
0
0
10sec.
0
1
15sec.
1
0
20sec.
1
1
5
Answering 
machine call 
number setting
Used to set the number of calls to switch to auto receive when 
answering telephone is not called in when the receive mode is set 
to the answering telephone connection mode.
Setting is made in binary input.
Binary input
5 times
0
6
1
7
0
Bit No.
Set range
5
6
7
8
0 to 15 times
8
1
S
W
36
1
CNG detection 
completion time
Used to set the time for completion of CNG signal/mute detection in 
the answering telephone connection mode.
Count is made from the last call signal.
45sec.
0 When a value outside the 
set range is set, the initial 
value is set.
2
0
3
1
4
Setting is made in binary input.
0
5
Binary input
1
6
Bit  No.
Set range
1
2
3
4
5
6
7
8
1 to 255sec.
1
7
0
8
1
SW 
NO.
Data 
No.
Item
Switch selection and contents of functions
Initial value
Remark
Page of 56