Read Sharp MX-B201D (serv.man6) Service Manual online
MX-FX12 FAX SOFT SWITCH 2 - 10
S
W
33
1
Page number print
setup
setup
Used to set whether the page number is added to the sender
information print or not.
information print or not.
Yes
1
1: Yes
0: No
2
Inhibited to use
0
3
0
4
0
5
0
6
0
7
0
8
Reception data
duplex print
duplex print
Used to set whether duplex print of received data is made or not.
No
0
Refer to User program
“DUPLEX RCV”.
“DUPLEX RCV”.
1: Yes
0: No
S
W
34
1
Flash send wait
time (U.S.A.,
Canada, U.K.,
Netherlands,
Luxembourg,
Belgium, France,
Australia, New
Zealand: Inhibited
to use)
time (U.S.A.,
Canada, U.K.,
Netherlands,
Luxembourg,
Belgium, France,
Australia, New
Zealand: Inhibited
to use)
Used to set the time from off-hook to Flash send.
1sec.
0
Bit No.
1
2
0sec.
0
0
0.5sec.
0
1
2
1sec.
1
0
0
2sec.
1
1
3
Inhibited to use
0
4
0
5
Signal send level
Max.
Max.
Used to set the max. signal send level.
Binary input
Binary input
–8dBm
1
6
0
7
Bit No.
Set range
Set range
5
6
7
8
0 (0dBm) to 15 (–15dBm)
0
8
0
S
W
35
1
Cover function
default setup
default setup
Used to set whether cover is added as default or not.
When auto clear is made by pressing [Clear All] key, the machine
returns to this setting.
When auto clear is made by pressing [Clear All] key, the machine
returns to this setting.
No
0
1: Yes
0: No
2
Answering
machine
connection
machine
connection
Setting to make them connect telephone that has answering
machine function as external telephone, and unite answering
machine function to fax receiver function.
When an absent function of an external telephone is used, it sets it
to “ON”.
The setting simultaneously with the dial-in function is improper.
machine function as external telephone, and unite answering
machine function to fax receiver function.
When an absent function of an external telephone is used, it sets it
to “ON”.
The setting simultaneously with the dial-in function is improper.
ON
1
1: ON
0: Off
3
CI delete max.
OFF time
OFF time
Used to set the max. wait time between detection of CI signal
pulse (number of times) and detection of the next CI signal
pulse.
pulse (number of times) and detection of the next CI signal
pulse.
If CIK signal pulse is not detected within this time, the number of
calls up to that time is cleared.
calls up to that time is cleared.
5sec.
0
4
Bit No.
3
4
0
5sec.
0
0
10sec.
0
1
15sec.
1
0
20sec.
1
1
5
Answering
machine call
number setting
machine call
number setting
Used to set the number of calls to switch to auto receive when
answering telephone is not called in when the receive mode is set
to the answering telephone connection mode.
Setting is made in binary input.
Binary input
answering telephone is not called in when the receive mode is set
to the answering telephone connection mode.
Setting is made in binary input.
Binary input
5 times
0
6
1
7
0
Bit No.
Set range
Set range
5
6
7
8
0 to 15 times
8
1
S
W
36
1
CNG detection
completion time
completion time
Used to set the time for completion of CNG signal/mute detection in
the answering telephone connection mode.
Count is made from the last call signal.
the answering telephone connection mode.
Count is made from the last call signal.
45sec.
0 When a value outside the
set range is set, the initial
value is set.
value is set.
2
0
3
1
4
Setting is made in binary input.
0
5
Binary input
1
6
Bit No.
Set range
Set range
1
2
3
4
5
6
7
8
1 to 255sec.
1
7
0
8
1
SW
NO.
Data
No.
Item
Switch selection and contents of functions
Initial value
Remark
Click on the first or last page to see other MX-B201D (serv.man6) service manuals if exist.