MX-5500N, MX-6200N, MX-7000N (serv.man60). LSU Section-Detailed section - Sharp Copying Equipment Service Manual (repair manual). Page 5

Read Sharp MX-5500N / MX-6200N / MX-7000N (serv.man60) Service Manual online

MX-7000N  LSU SECTION  i – 5
4)
Disconnect the connectors (F), and remove the screws (G)
and the screw (H), and remove the LSU CNT PWB (I).
* When installing, first of all install the screw (H).
* When installing, engage the PWB to the pawl (J).
c. LSU cooling fan motor
1)
Remove the left cabinet. (Refer to the “[A] EXTERNAL OUT-
FIT“)
2)
Remove the LSU. (Refer to the "(1) LSU".)
3)
Remove the screws (A), and remove the earth wire (B).
Remove the cover (C).
* When installing the cover (C), engage the pawls (D) to cover
lower (E). At this time be careful it bite the wire.
4)
Remove the screws (F), and remove the cover (G).
* When removing the cover (G), be careful to work place and
method, to don't enter the dust into the unit. Trouble (image
not fully etc.) may occur.
* When installing the cover, lock the pawl (H).
5)
Disconnect the connector (I). Remove the molt (J), and
remove the LSU cooling fan motor (K).
* When installing, point at the direction of outside with the
arrow (L).
d. Polygon motor, LSU thermistor 2
1)
Remove the left cabinet. (Refer to the “[A] EXTERNAL OUT-
FIT”.)
2)
Remove the LSU. (Refer to the "(1) LSU".)
Unit
Parts
1
LSU
c
LSU cooling fan motor
F
F
H
G
I
G
1-b
J
1-c
B
C
D
D
E
A
Unit
Parts
1
LSU
d
Polygon  motor
e
LSU thermistor 2
G
F
H
K
J
I
1-c
J
K
I
L
1-e
1-d
Page of 10
Display

Click on the first or last page to see other MX-5500N / MX-6200N / MX-7000N (serv.man60) service manuals if exist.