MX-5500N, MX-6200N, MX-7000N (serv.man60). LSU Section-Detailed section - Sharp Copying Equipment Service Manual (repair manual). Page 4

Read Sharp MX-5500N / MX-6200N / MX-7000N (serv.man60) Service Manual online

MX-7000N  LSU SECTION  i – 4
1)
Open the front cabinet (A).
2)
Remove the claning rod (B).
3)
Check the dirt of the cleaning base (C) (tip of the cleaning rod).
* When cleaning base is dirty, replace it. (Refer to the "B. Oth-
ers".)
4)
Insert the cleaning rod (B) in the hole which cleaning is
required so that the cleaning base is made downward slowly.
5)
Insert the cleaning rod (B) all the way and slide it back and
forth a few times for cleaning.
6)
Clean all the cleaning holes (D) (4-positions) on the dustproof
glass.
* When the cleaning base became extremely dirty, replace it.
(Don't cleaning use dirty cleaning base other dustproof
glasses.)
b. LSU CNT PWB
1)
Remove the left cabinet. (Refer to the “[A] EXTERNAL OUT-
FIT”.)
2)
Remove the LSU. (Refer to the "(1) LSU".)
3)
Remove the screws (A), and remove the earth wire (B).
Remove the cover (C).
* When installing the cover (C), engage the pawls (D) to cover
lower (E). At this time be careful it bite the wire.
A
B
C
B
B
B
Unit
Parts
1
LSU
b
LSU CNT PWB
D
1-a
1-b
B
C
D
D
E
A
Page of 10