MX-5500N, MX-6200N, MX-7000N (serv.man46). Simulation - Sharp Copying Equipment Service Manual (repair manual). Page 18

Read Sharp MX-5500N / MX-6200N / MX-7000N (serv.man46) Service Manual online

MX-7000N  SIMULATION  7 – 18
 
7-6
Purpose
Setting
Function (Purpose) Used to set the intermittent aging cycle.
Section
Operation/Procedure
1)
Enter the intermittent aging cycle (unit: sec) with 10-key.
2)
Press [OK] key.
The time entered in procedure 1) is set.
* The interval time can be set in the range of 1 to 900sec.
 
7-8
Purpose
Operation display
Function (Purpose) Used to display the warm-up time. 
Section
Operation/Procedure
Press [EXECUTE] key.
Counting of the warm-up time is started.
* Interruption of counting by pressing [EXECUTE] key is inhibited. 
 
7-9
Purpose
Operation test/Check
Function (Purpose) Used to set a color in the color mode print-
ing. (Used to check the print in the color
mode.)
Section
Operation/Procedure
1)
Select a color for print with the touch panel. 
2)
Press [EXECUTE] key.
Printing is started in the selected color.
* If no color is specified, printing is made in all colors.
 
8
 
8-1
Purpose
Operation test/Check/Adjustment
Function (Purpose) Used to check and adjust the operations of
the developing voltage in each print mode
and the control circuit.
* When the middle speed is adjusted, the
high speed and the low speed are also
adjusted simultaneously.
Section
Process (Developing)
Operation/Procedure
1)
Select a speed with [MIDDLE] and [LOW] key on the touch
panel. 
2)
Select an adjustment item with [
↑] and [↓] keys.
3)
Enter the adjustment value with 10-key.
* When U or V key is pressed, the set value of each item is
increased or decreased by 1 collectively.
4)
Press [EXECUTE] key.
The voltage entered in step 2 is outputted for 30sec and the
set value is saved. 
When [EXECUTE] is pressed, the output is interrupted.
K
Setup/cancel of black
C
Setup/cancel of cyan
M
Setup/cancel of magenta
Y
Setup/cancel of yellow
A :
1
;
CYCLE TIME(SEC)
A:
SIMULATION NO.07-06
INTERVAL AGING CYCLE TIME SETUP
1
1
900
OK
TEST
CLOSE
SIMULATION NO.07-08
TEST
WARM UP TIME DISPLAY SETTING
CLOSE
EXECUTE
0
SECONDS
Key
Item
Display
Content
Set 
range
Default 
value
MIDDLE
A
MIDDLE 
SPEED 
DVB_K
K developing bias 
set value at middle 
speed
0 - 700
450
B
MIDDLE 
SPEED 
DVB_C
C developing bias 
set value at middle 
speed
0 - 700
450
C
MIDDLE 
SPEED 
DVB_M
M developing bias 
set value at middle 
speed
0 - 700
450
D
MIDDLE 
SPEED 
DVB_Y
Y developing bias 
set value at middle 
speed
0 - 700
450
LOW/
HIGH
A
LOW 
SPEED 
DVB_K
K developing bias 
set value at low 
speed
0 - 700
420
B
LOW 
SPEED 
DVB_C
C developing bias 
set value at low 
speed
0 - 700
420
C
LOW 
SPEED 
DVB_M
M developing bias 
set value at low 
speed
0 - 700
420
D
LOW 
SPEED 
DVB_Y
Y developing bias 
set value at low 
speed
0 - 700
420
E
HIGH 
SPEED 
DVB_K
K developing bias 
set value at high 
speed
0 - 700
450
CLOSE
K
SIMULATION NO.07-09
TEST
PRINTING COLOR SELECT(COLOR MODE)
C
M
Y
1/1
EXECUTE
Page of 127
Display