Error codes and conditions
Network
If you suspect a network problem, consider the following:
• If the Fiery X3eTY2 does not appear in the list of printers on the network, there may be another device on the network with the 
same Ethernet hardware address. 
• There may be conflicting network settings in Setup and on the customer’s workstation. 
• Inappropriate Setup options may cause printing problems.
• Missing or incorrectly placed printer description files may cause application-specific printing errors.
For additional information, see Configuration and Setup on the User Documentation CD.
Cannot connect 
to the network, 
or neither LED on the 
10/100/1000BaseT 
network connector is lit
One of the following:
• Cable is connected to the wrong 
port.
• Faulty network cable or connection
• Faulty network
• Faulty Ethernet interface on 
the motherboard
1. Make sure that the network cable is the correct category 
of straight-through Ethernet cable and connected to the 
designated network port on the Fiery X3eTY2 connector 
panel (see page 48).
2. Check the cable connection to the network. 
3. Replace the cable with a new or tested cable.
4. Request that the network administrator check Network 
Setup.
5. Request that the network administrator check other 
devices on the network.
If other devices are not functioning, it could be a problem 
with the network.
6. If the rest of the network is functioning properly and 
the problem persists, clear the CMOS and power-up 
settings (see page 89).
7. Replace the motherboard.
T
ABLE
 B
Fiery X3eTY2 error codes and conditions (Continued)
Symptom
Possible cause
Suggested action 