Read Sharp MX-5050N / MX-5050V / MX-5070N / MX-5070V / MX-6050N / MX-6050V / MX-6070N / MX-6070V (serv.man35) Technical Bulletin online
【Description】・・・(1)
No.
Item
Description
Model
MX-3050N
MX-3550N
MX-4050N
MX-3550N
MX-4050N
MX-3060N
MX-3560N
MX-4060N
MX-3070N
MX-3570N
MX-4070N
MX-3560N
MX-4060N
MX-3070N
MX-3570N
MX-4070N
MX-5050N
MX-6050N
MX-6050N
MX-5070N
MX-6070N
MX-6070N
28
Main unit
control
Correction of failure to reboot MFP after firmware update
○
○
○
○
29
Main unit
control
Collecting all log data in one folder in thumb drive when SIM56-99 (batch log data
collection) is executed.
○
○
○
○
30
Main unit
control
Correction of machine lockup which may occur when authentication using an IC card is
executed while primarily requesting the authentication to an authentication server
○
○
○
○
31
Main unit
control
Correction of machine lockup which occurs while searching an address in the Address
Book
○
○
○
○
32
Main unit
control
Correction of failure with keyboard
The operating “CAPS” key on software keyboard turns on the Num Lock on external
keyboard being connected, illuminating the LED.
○
○
○
○
33
Main unit
control
Correction of recording unnecessary logs in Active Directory environment
○
○
○
○
34
Main unit
control
Correction of MPF reboot after execution of User Control -> User Count -> Save User
Count -> Print and Delete the Data
○
○
○
○
35
Main unit
control
Correction of fuser motor keeps running with low speed after opening Right cover
○
○
○
○
36
Main unit
control
Review of temperature correction during job (increased by 5-degree)
○
○
NA
NA
37
Main unit
control
Correction of H3-01 occasionally caused by printing a large number of envelopes
○
○
○
○
38
Main unit
control
Modification of software control to prevent H3 trouble due to overshoot.
○
○
○
○
39
Main unit
control
Fusing belt unit for MX-5050N/5070N/6050N/6070N series was changed from May
2017 production. For the purpose to avoid the low temperature offset, the fusing
temperature control function has been added to Soft SW and the default value has
been changed.
For machines before May 2017 production, the modification has been made so that
the set value does not automatically change even when updating the firmware to this
version.
If the set value is manually changed from 0 to 1, the high temperature offset may
occur.
In addition, if the setting of Soft SW is changed from 0 to 1 while the fusing belt unit
before May 2017 production is installed, the high temperature offset may occur.
*Changed fusing unit is supplied as the service parts. This will be announced on
Service Information later.
SIM55-1 SW No.22 Data 8
MX-5150FN/6150FN/5170FN/6170FN series
0: Not control the temperature
1: Control the temperature (Default)
MX-3050N/3550N/4050N/3060N/3560N/4060N/3070N/3570N/4070N series
0: Not control the temperature
1: Not control the temperature (Default)
*On MX-3050N/3060N/3070N series, both 0 and 1 are set to “Not control the
temperature” because Fusing belt unit has not been changed.
NA
NA
○
○
○=applied
Click on the first or last page to see other MX-5050N / MX-5050V / MX-5070N / MX-5070V / MX-6050N / MX-6050V / MX-6070N / MX-6070V (serv.man35) service manuals if exist.