Read Sharp MX-4100N / MX-4101N / MX-5000N / MX-5001N (serv.man38) Service Manual online
MX-4100N Dehumidifying heater 24 – 6
4)
Install the scanner heater and secure it with the screw (M4x6
Bind machine screw) (package part No. 18). Pass the harness
through the clamp.
Bind machine screw) (package part No. 18). Pass the harness
through the clamp.
NOTE: The convex part of the scanner heater must be inserted
into the hole of the scanner frame.
5)
Tighten the loose scanner heater harness by pulling it in the
arrow direction and secure it with the snap band (packing part
No. 19) then cut its tip to approx. 5 mm or less.
arrow direction and secure it with the snap band (packing part
No. 19) then cut its tip to approx. 5 mm or less.
6)
Move the lamp unit by hand and check that it move smoothly in
all movable area.
all movable area.
NOTE: Check that there is no interference of the harness of the
scanner heater in the wire and the 2/3 mirror unit.
(4) Installation of the table glass, the paper exit cover
1)
Install the paper exit cover.
2)
Install the table glass. Install the SPF glass and the glass
holder, and secure it with the screw.
holder, and secure it with the screw.
F. Installation of the desk heater kit
(1) Assembling of the desk heater
1)
Attach the desk heater (package part No. 20) to the heater
heat sink (package part No. 21), and secure it with the screw
(M3x4 S-tight) (package part No. 22).
heat sink (package part No. 21), and secure it with the screw
(M3x4 S-tight) (package part No. 22).