Read Sharp MX-3050N / MX-3060N / MX-3070N / MX-3550N / MX-3560N / MX-3570N / MX-4050N / MX-4060N / MX-4070N (serv.man170) Technical Bulletin online
Sharp Electronics (UK) Ltd., Document Systems Support
64
Network
Correction of the problem that the print occasionally cannot be performed
on the machine in wireless connection due to the lockup.
○
○
Done
Done
65
Network
There was no description of Google Cloud printer setting/ Mopria setting/
Collaboration with Cloud in Network setting list. Description above has
been added.
○
○
Done
Done
66
Network
Correction of very rare case with the network connection failure after the
reboot
○
○
Done
Done
67
Network
Correction of the problem that the user fails to re-log in after the lapse of
10hours from his/her first log-in when using Active Directory authentication
○
○
Done
Done
No.
Item
Description
Model
MX-3050N
MX-3550N
MX-4050N
MX-3550N
MX-4050N
MX-3060N
MX-3560N
MX-4060N
MX-3070N
MX-3570N
MX-4070N
MX-3560N
MX-4060N
MX-3070N
MX-3570N
MX-4070N
MX-5050N
MX-6050N
MX-6050N
MX-5070N
MX-6070N
MX-6070N
68
Network
Correction of the connection error which may be caused during forwarding
the FAX reception data via network
○
○
Done
Done
69
Network
Correction of the problem that the user name cannot be displayed when
logging in using IC card of the user registered to MFP in Active Directory
authentication
○
○
Done
Done
70
Simulation
For Waste Toner Near End Alert MIB, the feature to support the differences
on the behavior depending on OS version has been added to Soft SW:
SIM55-3 SW32 Data 4
0:RFC compliant (Default)
1:RFC non-compliant
○
○
○
○
71
Simulation
Following feature has been added:
- EEPROM data is stored on a regular basis, and
- Backup data is restored to EEPROM with SIM56-15 when the problem
occurs.
○
○
○
○
72
Simulation
Correction of the problem that Auto Paper Selection does not work right
after shifting to the SIM test mode
○
○
○
○
73
Simulation
Correction of the following problem:
If the service password check to enter the simulation is set up (Sim26-79 B
0→1), when U2-XX trouble relating to the authentication occurs, the
operator may not be able to enter the simulation and the trouble cannot be
0→1), when U2-XX trouble relating to the authentication occurs, the
operator may not be able to enter the simulation and the trouble cannot be
cleared.
○
○
○
○
74
Simulation
Wordings for other languages than Japanese/English in SIM language list
have been partly corrected.
○
○
○
○
75
Simulation
Correction of failure to output List Print
○
○
○
○
76
Simulation
Modification has been made to detect the damage in the filling area and
notify the damage as E7-03 (Sub code: 0x14) trouble.
*When E7-03 (Sub code: 0x14) trouble occurs, the filling area can be
recovered by formatting the filling area with SIM62-11. However, the filling
data itself cannot be restored.
○
○
Done
Done
77
Simulation
Addition of the staple position adjustment feature for Saddle Stitch
SIM3-10
Saddle Stitch position adjustment All sizes
Saddle Fold position adjustment All sizes
○
○
Done
Done
78
Simulation
Correction of failure to recover from an ASIC error
An error with ASIC is indicated after firmware upgrade on rare occasions.
The MFP won’t recover unless Flash ROM is replaced.
The MFP won’t recover unless Flash ROM is replaced.
○
○
Done
Done
79
Simulation
Addition of PRINTER CONTROL feature to SIM26-03 (Auditor setting)
○
○
Done
Done
80
Simulation
Addition of the item of density adjustment timing to SIM44-28
○
○
Done
Done
○=applied