IMAGE SEND MODE,FAX MODE JOB LOG CODE LIST(CODE C)
CONTENTS OF CODE
CODE C
Content of communication interruption
Send/Receive
00
When the conditions after 01 do not apply.
Send/Receive
01
Send length over
Send
02
EOL time up
Receive
03
Carrier detection time up
Receive
04
Time up of the communication start command from the machine side
Receive
05
Time up in phase C (8 min)
Send
06
Memory image decode error
Receive
07
Memory image decode error
Send
08
Time up between frames in phase C (Report code is 0 or 16.)
Send/Receive
09
Not used
-
10
Not used
-
11
Polarity reversion detection
Receive
12
Invalid command reception
Receive
13
Time up (1-minute timer/6-second time)
Receive
14
PUT error
Receive
15
In V.34 mode, time up is generated when shifting from Primary to Control. Receive
16
In V.34 mode, time up is generated when shifting from Control to Primary. Receive
17
Command receive time-up from MFP controller
Receive
18
Not used
-
19
Not used
-
20
Polarity reversion detection
Send
21
Invalid command reception
Send
22
Fallback retry number over
Send
23
Command retry number resend over
Send
24
Time up (T5 timer)
Send
25
Time up (T5 timer) in V.34 mode
Send
26
In V.34 mode, time up is generated when shifting from Primary to Control. Send
27
In V.34 mode, time up is generated when shifting from Control to Primary. Send
28
When sending the FSK signal, no response of send completion is sent back
from the MODEM chip within a certain time. (V.34, other than V.34)
Send
29
Not used
-
30
A communication error is generated between MFP controller and Modem
controller. (Report code is 0 or 16.)
-
31
DC current not detected (busy)
Send
32
Dial tone not detected (busy)
Send
33
Busy tone detection (busy)
Send
34
T0 time up (Remote machine not responding)
Send
35
T1 time up (Remote machine not responding)
Send
36
In dialing, polarity reversion detection (Remote machine not responding)
Send
37
Calling is not made (busy)<Collision detected (including CNG detection)>
Send
38
Not used
-
60
In resend of document filed data, an error occurs in decoding or coding.
Resend
61
In resend of document filed data, setting to inhibit resolution conversion is
made. (The resolution after resend is set to be Enlarged.)
Resend
62
In resend of document filed data, rotation setting is made for data which
cannot be rotated.
Resend
63
In resend of document filed data, data cannot be stored in HD after
conversion of resolution for resend.
Resend
64
In resending data of document file, during conversion for resending, the
number of IMS management pages exceeds the upper limit (999). (IT
occurs in OSA Scan to FTP also, resulting in memory over.)
Resend
OSAScanToFTP
70
E-mail header acquisition error
E-mail receive
71
Time out occurs during e-mail receive.
E-mail receive
72
Receive reject occurs during e-mail receive.
E-mail receive
73
Network communication cannot be made due to port disable.
Network send