4) Remove the front cover.
Pull out the paper cassette. Push the both sides of the front
cover to bend it inward, and remove it from the hinge arm of
the copier.
5) Remove the front cover and the right cover of the copier.
Open the document cover. Remove the fixing screws (5 pcs.)
of the right cover, and remove the right cover.
Then remove the fixing screws (12 pcs.) of the front cover, and
remove the front cover. At that time, pull out the flat cable from
the operation panel at first. Since the grounding wire is con-
nected to the front cabinet, put the front cabinet on the left side
of the copier.
6) Cut off the paper exit auxiliary mylar, and attach the FULL detec-
tion mylar. (This procedure is performed only in Japan.)
Cut off the two paper exit mylars inside the copier with scis-
sors. Then clean and remove oil from the attaching surface of
the FULL detection lever, and attach the FULL detection mylar
as shown in the figure.
7) Shift the separator lever.
Turn the separator gear to move the lever upward until it stops.
8) Install the separator tray.
Put the separator tray inside the copier, and engage the R/F
bosses of the separator tray with the R/F sides of the separator
lever of the copier, and install the separator tray to the copier.
9) Cut off the optical molt. (If there is no optical molt, this procedure
is not required.)
If the optical molt is considerably long, cut off the shaded sec-
tion of the separator motor installing section in the right frame
of the copier with a cutter.