A. Sensor PWB
1) Remove two screws from the bottom of the pickup unit.
2) Remove the upper cover.
1) Remove two screws.
2) Remove the sensor PWB.
3) Remove the harness.
B. Pickup solenoid
1) Remove two screws.
2) Remove the pickup solenoid
*
When installing, hang iron core A on the solenoid arm.
C. Clutch
1) Remove the E-ring.
2) Remove the pulley and bush.
3) Slide the bush in the arrow direction.
4) Lift the clutch, and 5) remove the clutch.
1) Remove the E-ring.
2) Remove the parts.
D. Manual paper feed roller, pickup roller
1) Lift the paper stopper.
2) Slide the takeup roller unit.
3) Slide the bush in the arrow direction.
4) Remove the takeup roller unit.