AR-RP9. Complete - Sharp Copying Equipment Service Manual (repair manual). Page 4

Read Sharp AR-RP9 Service Manual online

AR-RP9/SP9/AR-D33  UNPACKING AND INSTALLATION  2 - 1
[2] UNPACKING AND INSTALLATION
1. AR-SP9/RP9 Installation
The installing procedures below are described for the AR-SP9. The
installing procedures for the AR-RP9 are the same as below.
Turn the main switch to the “OFF” position and remove the power
plug from the outlet.
1)
Remove the document cover.
Remove the document cover from the copier.
2)
Remove the rear cabinet.
Remove the three screws and then remove the rear cabinet.
3)
Replace the right glass holder (For Europe only).
<1> Remove the two screws, and remove the right exterior
OC.
<2> Attach the right glass holder, and fix it with the two screws
which was removed in the above procedure.
Installation manual: 1 sheet
Parts included
Right glass holder: 1 pc.
(For Europe only)
Screw (M3 x 8): 1 pc.
Screw (M3 x 6): 1 pc.
AR-SP9 Unit (SPF Unit)
AR-RP9 Unit (RSPF Unit)
"OFF"
Page of 28
Display