AR-RF3 (serv.man2). AR-RF3 Service Manual - Sharp Copying Equipment Service Manual (repair manual). Page 8

Read Sharp AR-RF3 (serv.man2) Service Manual online

AR-RF3  MACHINE OPERATIONS  4 - 1
[4] MACHINE OPERATIONS
When original is detected in the original tray, EMPS turns ON (no-output level).
Original size is determined by DWVR, DLS1 and DLS2.
Two operation modes, single-side and duplex, are available.
For single-side, after the print SW is turned ON, DFM rotates in the forward direction and the original is transported. (DTM and DEM forward rotation
begins.)
REGS detects the leading edge of the fed original (REGS output level HIGH); the original contacts the resist rollers and stops.
The DFM reverses its rotation direction , the resist rollers rotate, and the document is transported.
The TIMS detects the leading edge of the original, and the DFM turns OFF.
After the DTM and DEM stop, the DTM rotates forward, and the transport belt moves. Or, the DFM reverses its direction of rotation, and the original is
sent to the transport section.
When the TIMS detects the trailing edge of the original, the DFM stops, after which the DTM (transport belt) also stops. After scanning is completed,
the DTM and DEM turn ON, and the original is discharged. After the DES detects the trailing edge of the original, the DTM and DEM turn OFF (stop).
(3)(11) (7)(10)
(1) (4) (6)
(8) (9)
(12)
1
2
5
6
3
4
7
8
9 10
+5V
DW
R
A
GND
DLS1
A
GND
+5V
+5V
A
GND
DLS2
(NC)
2
1
DRSOL
+24V
CN4 (10pin)
CN10 (2pin)
CN9 (6pin)
CN7 (7pin)
CN8 (6pin)
1
2
+24V
PGND
3
4
+5V
SGND
CN1 (4pin)
6
5
ADS
TXD
4
3
RXD
DTR
2
1
DSR
RESET
CN2 (6pin)
1
2
5
6
3
4
+5V
DRS
A
GND
DES
DRS D
A
+5V
CN3 (9pin)
4
5
11 12
6 10
13 14 15
+5V
A
GND
REGS
REGS D
A
EMPS
+5V
+5V
TIMS
TIMS D
A
CN5 (15pin)
RADF CONTROL PWB
MFP PWB
1
3
TXD-RADF
RXD-RADF
5
7
DTR-RADF
DSR-RADF
9 11
RES-RADF
13
RADF UP
2
4
+5V
+5V
6
+24V
+5V OP
CN11 (16pin)
8 10
+24V
12
GND
GND
BR
BL
PL
LB
PK
BL
OR
OR
RD
OR
RD
GY
GY
5
FG
11
10
GND
GND
3
7
+24V
1
RADF UP
2
9
+5V OP
RES-RADF
8
DSR-RADF
+5V
(12pin)
12
6
DTR-RADF
4
TXD-RADF
RXD-RADF
5
11
10
3
7
1
2
9
8
12
6
4
3
2
1
+5V
A
GND
DLS2
3
2
1
+5V
DRS
DRS D
A
1
2
5
6
3
4
DEM B\
DEM B
+24V
+24V
DEM A\
DEM A
1
2
5
6
3
4
DFM A
+24V
+24V
DFM B\
DFM A\
DFM B
3
2
1
+5V
A
GND
DLS1
1
2
3
REGS D
A
REGS
+5V
1
2
3
TIMES D
A
TIMS
+5V
1
2
3
EMPS
A
GND
+5V
3
2
1
+5V
A
GND
DLS1
1
2
3
DTM
Transport motor
DFM  
Document feed motor
DLS2
Original length sensor 2
DLS1
Original length sensor 1
DWVR
Original volume
EMPS
Empty sensor
TIMS
Timing sensor
DRSOL
Reverse solenoid
DRS
DES
3
2
1
+5V
AGND
DES
3
2
1
1
2
3
+24V
DRSOL
7
6
3
2
5
4
DTM B\
DTM B
(NC)
+24V
DTM A\
DTM A
1
+24V
GY
ELR/P
Connector
Pin No.
Reverse
Delivery 
motor
DEM
Resist sensor
REGS