AR-RF3  UNPACKING AND INSTALLATION  2 - 2
(2) Attach the B/W scanner module/DSPF to the 
main unit.
1) Cut and remove the two cut-out portions from the rear of the upper
cabinet of the main unit using a tool such as diagonal cutting tool.
2) Attach the two RADF mounting screws to the mounting holes pre-
pared in 1).
3) Lift the B/W scanner module/DSPF, fit the holes in the hinge sec-
tions of the B/W scanner module/DSPF to the RADF mounting
screws that have been attached in 2), move the B/W scanner mod-
ule/DSPF toward the front, and secure it with the two RADF secur-
ing screws.
(3) Adjust the angle of the B/W scanner module/
DSPF.
Loosen the two angle adjusting plate securing screws on the hinge
angles. While raising the angle adjusting plates to the limit as shown in
the illustration, tighten the loosened screws.
Note: Be sure to check that the projections on the angle adjusting
plates are inserted securely into the long holes of the hinges.
(4) Connect the RADF connectors.
1) Remove the screw from the connector cover on the rear side of the
main unit and then remove the connector cover.
2) Connect the RADF connector to the connector of the main unit and
tighten the screw on the connector to secure it.
Cut-out portions
RADF mounting screw
RADF mounting screw
RADF securing screw
RADF securing screws
RADF mounting screw
Angle adjusting plate
Hinge angle
Long holes
Angle adjusting
plate securing
screws
Connector cover
RADF connector
Screw