AR-P350, AR-P450 (serv.man8). ARP350 and ARP450 Service Manual - Sharp Copying Equipment Service Manual (repair manual). Page 76

Read Sharp AR-P350 / AR-P450 (serv.man8) Service Manual online

AR-P350 TROUBLE CODES-5
F2
39
Content
Process thermistor trouble
Detail
Process thermistor open
Cause
Process thermistor trouble
Process thermistor harness disconnection
PCU PWB trouble
Check and 
remedy
Check connection of harness and connector 
of the process thermistor.
Check PCU PWB.
F3
12
Content
Machine no. 1 tray lift-up trouble
Detail
PED does not turn ON in the specified time.
LUD does not turn ON in the specified time.
Cause
PED/LUD trouble
No. 1 tray lift-up trouble
Check connection of harness between the 
PCVU PWB, lift-up unit, and paper feed unit.
Check and 
remedy
Check PED, LUD, and their harness and 
connectors.
Check the lift-up unit. 
22
Content
Machine No. 2 tray lift-up trouble
Detail
MCPED does not turn ON in the specified 
time.
MCLUD does not turn ON in the specified 
time.
Cause
MCPED/MCLUD trouble
No. 2 tray lift-up motor trouble
Harness disconnection f the PCU PWB, the 
lift-up unit, and the paper feed unit.
Check and 
remedy
Check MCPED, PCLUD, and their harness 
and connectors. 
Check the lift-up unit. 
H2
00···
HL1
(RT
H1)
01···
HL2
(RT
H2)
Content
thermistor open
Fusing unit not installed
Detail
Thermistor is open. 
(An input voltage of 2.92V or above is 
detected.)
Fusing unit not installed
Cause
Thermistor trouble
Control PWB trouble
Fusing section connector disconnection
AC power trouble
Fusing unit not installed
Check and 
remedy
Check harnesses and connectors from the 
thermistor to the control PWB.
Use DIAG (SIM14) to clear the self diag 
display.
H3
00···
1HL1
(RT
H1)
01···
HL2
(RT
H2)
Content
Fusing section high temperature trouble
Detail
The fusing temperature exceeds 242°C. 
(An input voltage of 0.27V or above is 
detected.)
Cause
thermistor trouble
Control PWB trouble
Fusing section connector disconnection
AC power trouble
Check and 
remedy
Use DIAG (SIM5-2) to check the heater lamp
Blinking operation.
If the heater lamp blinks normally:
Check the thermistor and its harness.
Check the thermistor input circuit in the 
control PWB.
If the heater lamp keep lighting:
Check the AC PWB and the lamp control 
circuit in the control PWB.
Use DIAG (SIM14) to cancel the trouble
MAIN
SUB
H4
00···
1HL1
(RT
H1)
01···
HL2
(RT
H2)
Content
Fusing section low temperature trouble
Detail
•The set temperature is not reached within
the specified time (normally 3 min) when
warming up or resetting from pre-heating.
•Under the ready state. 
(An input voltage of 1.21V or below is
detected 5 times continuously.)
Cause
thermistor trouble
Heater lamp trouble
Control PWB trouble
Thermostat trouble
AC power trouble
Interlock switch trouble
Check and 
remedy
Use DIAG (SIM5-2) to check the heater lamp
Blinking operation.
If the heater lamp blinks normally:
Check the thermistor and its harness.
Check the thermistor input circuit in the 
control PWB.
If the heater lamp does not light:
Check for heater lamp disconnection and 
thermostat disconnection.
Check the interlock switch.
Check the AC PWB and the lamp control 
circuit in the control PWB.  
Use DIAG (SIM14) to cancel the trouble.
H5
01
Content
5-time continuous POD1 not-reaching jam 
detection
Detail
5-time continuous POD1 not-reaching jam 
detection
Cause
A fusing section jam is not properly removed. 
(Jam paper remains.)
POD1 sensor trouble, or harness 
disconnection
Improper installation of fusing unit
Check and 
remedy
Check jam paper in the fusing section. 
(winding, etc.)
Check POD1 sensor harness, and check 
installation the fusing unit.
Use DIAG (SIM14) to cancel the trouble.
L4
01
Content
Main motor lock detection
Detail
The motor lock signal is detected for 1.5sec 
during rotation of the main motor.
Cause
main motor trouble
Check connection of harness between the 
PCU PWB and the main motor. 
Control circuit trouble
Check and 
remedy
Use DIAG (SIM25-1) to check the main 
motor operation.
Check harness and connector between the 
PCU PWB and the main motor.
02
Content
Drum motor lock detection
Detail
The motor lock signal is detected for 1.5sec 
during rotation of the drum motor.
Cause
Drum motor trouble
Improper connection of harness between the 
PCU PWB and the drum motor.
Control circuit trouble
Check and 
remedy
Use DIAG (SIM25-1) to check the drum 
motor operation.
Check harness and connector between the 
PCU PWB and the drum motor.
MAIN
SUB
Page of 81
Display