AR-P350, AR-P450 (serv.man8). ARP350 and ARP450 Service Manual - Sharp Copying Equipment Service Manual (repair manual). Page 71

Read Sharp AR-P350 / AR-P450 (serv.man8) Service Manual online

AR-P350 DIAG-21
PROCESS DATA 
DISPLAY
Process control data display.
(LCD display)
*Pressing the [
] or [
] key selects the group.
*Pressing [OK] key displays the process control data.
*Using [MENU] moves to the next item
*Pressing [BACK/C] key terminates the process control data display mode.
group is:
XXX CHECK.
Controller port check.
(LCD display)
*Pressing the [
] or [
] key selects the port check mode.
*Pressing [OK] key start the port check.
*Pressing [BACK/C] key terminates the the port check mode.
SELECT IN SIGNAL 
SET
Select in signal setting.
(LCD display)
*Pressing [OK] key start the select in signal setting mode.
*Using the [
] and [
] keys changes the ON or OFF.
*Pressing [OK] key starts the select in signal setting.
*Pressing [BACK/C] key terminates the select in signal setting mode.
Menu
Content
Initial 
value
Set range
DRUM ADJ. (VG)
30
X:
A:
process control data
B:
toner control data
CENTRO PORT CHECK
OK
XXX:
CENTRO PORT CHECK
NIC CHECK (network interface card check)
SELECT IN SIGNAL SET
ON
Page of 81