AR-M700 (serv.man24). Details of each section - 9 Filters, 10 PWB section - Sharp Copying Equipment Service Manual (repair manual). Page 5

Read Sharp AR-M700 (serv.man24) Service Manual online

: Feb. 6 2004
1
AR-M550/M620/M700  DETAILS OF EACH SECTION  6 - 150
3) Remove the soft NIC PWB unit.
4) Remove the soft NIC PWB angle from the soft NIC PWB.
a-9. MFP FLASH ROM PWB
1) Pull out the NIC control unit. (See “a-8. Soft NIC PWB” in this sec-
tion)
2) Release the lock, and remove the MFP Flash PWB.
a-10. MFP controller PWB
1) Remove the manual feed cover F, the right cabinet middle, and the
right cabinet upper. (See “a-8. Soft NIC PWB” in this section)
2) Pull out the NIC control unit, and remove the flat cable. Release
the lock, and remove the NIC control unit.
3) Remove the Soft NIC PWB unit.
4) Remove the PWB protection plate. Remove the MFP controller
PWB.
1
Page of 5
Display

Download Sharp AR-M700 (serv.man24) Service Manual (Repair Manual)