AR-M700 (serv.man163). 007-Added protection has been added between the Document Detection Light-Receiving pwb and harness. - Sharp Copying Equipment Technical Bulletin (repair manual). Page 2

Read Sharp AR-M700 (serv.man163) Technical Bulletin online

Sharp Electronics (UK) Ltd., Technical Services Group
ARE698
*Attachment of harness protection sheet.
Procedure
1.Attach the ‘harness protection sheet’ onto the ORS PD PWB.
Ensure the surface is clean before attaching the protection sheet.
2. Hook the ‘harness protection sheet’ onto the rib of the holder.
*Please note
Be sure to install the ORS PD harness after the harness protection sheet is attached, and
hook the rib of the holder as it was before the modification procedure.
Ensure the harness is not between the pwb and sheet.