AR-M550 (serv.man15). (8) Simulation - Sharp Copying Equipment Service Manual (repair manual). Page 91

Read Sharp AR-M550 (serv.man15) Service Manual online

AR-M550/M620  SIMULATION  8 - 91
3) Enter the set value with 10-key.
4) Press [START] key.
The dial signal is sent with the set value + 29ms.
When [CUSTOM SETTINGS] key is pressed during execution, the
operation is stopped.
Operation/Procedure
1) Enter 0 with 10-key.
2) Press [START] key. 
The dial signal is outputted.
(Dial pulse make time setting)
1) Enter 1 with 10-key.
2) Press [START] key.
3) Enter the set value with 10-key.
4) Press [START] key.
The dial signal is sent with the set value + 9ms.
When [CUSTOM SETTINGS] key is pressed during execution, the
operation is stopped.
Operation/Procedure
1) Enter 0 with 10-key.
2) Press [START] key. 
The dial signal is outputted.
(Dial pulse make time setting)
1) Enter 1 or 2 with 10-key.
2) Press [START] key.
3) Enter the set value with 10-key.
4) Press [START] key.
When [CUSTOM SETTINGS] key is pressed during execution, the
operation is stopped.
0
EXECUTE
Execute
1
MAKE TIME
Dial pulse make time setting (0 - 15)
66-15
Purpose
Setting/Operation test/Check
Function
(Purpose)
Used to set the make time in the FAX pulse dial mode 
(20pps) and to test the dial signal output. (The dial 
number signal set by SIM 66-13 is outputted.) Used to 
check troubles in dialing and to check the operation. 
(Only when FAX is installed)
Section
FAX
Item
Operation
0
EXECUTE
Execute
1
MAKE TIME
Dial pulse make time setting (0 - 15)
SIMULATION 66-14
DIAL TEST(10PPS).  SELECT 0-15, AND PRESS START.
[1. MAKE TIME]
1
7
SIMULATION 66-14
DIAL TEST(10PPS). EXECUTE
1. MAKE TIME  
7
 ; [+29 ms]
SIMULATION 66-14
DIAL TEST(10PPS). SELECT 0-1, AND PRESS START.
0. EXECUTE
1. MAKE TIME  
7
 ; [+29 ms]
Press [CUSTOM SETTINGS] key.
Press [CUSTOM SETTINGS] key 
or press [START] key.
Select 1 and 
press [START] key.
Select 0 
and press 
[START] key. 
66-16
Purpose
Setting/Operation test/Check
Function
(Purpose)
Used to check the dial signal (DTMF) output in the FAX 
tone dial mode. (The dial number signal set by SIM 66-
13 is outputted.) The send level can be set to an 
optional level. Used to check troubles in dialing and to 
check the operation. (Only when FAX is installed)
Section
FAX
Item
Operation
Item
Set range
0
EXECUTE
Execution
1
HIGH
High group level
0 - 15dB
2
HIGH LOW
High group - Low group
0 - 15
SIMULATION 66-15
DIAL TEST(20PPS). SELECT 0-1, AND PRESS START.
0. EXECUTE
1. MAKE TIME  
7
 ; [+9 ms]
SIMULATION 66-15
DIAL TEST(20PPS).  SELECT 0-15, AND PRESS START.
[1. MAKE TIME]
1
7
SIMULATION 66-15
DIAL TEST(20PPS).  EXECUTING···.
1. MAKE TIME  
7
 ; [+9 ms]
Press [CUSTOM SETTINGS] key.
Press [CUSTOM SETTINGS] key 
or press [START] key.
Select 1 and 
press [START] key.
Select 0 
and press 
[START] key.
Page of 98
Display

Click on the first or last page to see other AR-M550 (serv.man15) service manuals if exist.