AR-M550/M620 SETTING AND ADJUSTMENTS 7 - 43
This adjustment is needed in the following situations:
• The original size sensor section has been disassembled.
• The original size sensor section has been replaced.
• U2 trouble has occurred.
• The scanner control PWB has been replaced.
• The EEPROM on the scanner control PWB has been replaced.
1) Go through the modes specified in Simulation 41-1.
2) Gradually turn over the original detection arm unit in the arrow
direction, and loosen the original cover switch actuator adjusting
screw so that the OCSW indicator changes from inverse video to
normal video when the arm unit top reaches a height of 32±0.5mm
from the table glass. Then move the actuator to adjust its position.
(If the original cover switch turns on in improper timing, the original
detection mechanism mail fail to operate correctly.)
screw so that the OCSW indicator changes from inverse video to
normal video when the arm unit top reaches a height of 32±0.5mm
from the table glass. Then move the actuator to adjust its position.
(If the original cover switch turns on in improper timing, the original
detection mechanism mail fail to operate correctly.)
1) Go through the modes specified in Simulation 41-2.
2) Open the original cover. With nothing placed on the original table,
select NO ORIGINAL using the numeric keypad.
3) Press the Start key
This sets the sensor level with no original detected.
4) Set A3 (11" x 17") paper on the original table, and select A3 ORIG-
INAL using the numeric keypad.
5) Press the Start key
This sets the sensor level with an original detected.
When each of the above operations has been completed, the "COM-
PLETE" message appears; when any of the operations has failed, the
"ERROR" message appears.
PLETE" message appears; when any of the operations has failed, the
"ERROR" message appears.
This adjustment is needed in the following situations:
• The operation panel has been replaced.
• U2 trouble has occurred.
• The MFP control PWB has been replaced.
• The EEPROM on the MFP control PWB has been replaced.
1) Go through the modes specified in Simulation 65-1.
2) Press the four cross mark points.
Pressing the cross mark points correctly results in gray display. When
the touch panel adjustment is complete with the four points pressed,
the sub-number entry screen for simulation reappears.
the touch panel adjustment is complete with the four points pressed,
the sub-number entry screen for simulation reappears.
If any error is detected, the touch panel returns to adjustment mode.
Note: Never use something with a sharp tip (such as a needle or pin)
to press the touch panel.
ADJ 15
Adjusting the original size
detection (in original table mode)
detection (in original table mode)
ADJ 15A
Adjust the detection point of the original
size sensor (in original table mode)
size sensor (in original table mode)
SIMULATION 41-1
PD SENSOR CHECK..
OCSW
PD1
PD2
PD3
PD4 PD5 PD6 PD7
32 5mm
+
-
Original detection
arm unit
arm unit
Table glass
Original cover switch actuator
ADJ 15B
Adjust the sensitivity of the original size
sensor
sensor
Select 2 and press [START] key.
(Error)
(Error)
Press [CUSTOM SETTINGS]
key.
key.
ADJ 16
Adjusting the touch panel
coordinates
coordinates
SIMULATION 41-2
PD SENSOR ADJUSTMENT. SELECT1-2, AND PRESS START.
(PLEASE OPEN THE ORIGINAL COVER.)
1. NO ORIGINAL
2. A3 ORIGINAL
1
SIMULATION 41-2
Press [CUSTOM SETTINGS] key.
Select 1 and
press [START] key.
press [START] key.
PD SENSOR ADJUSTMENT.
NO ORIGINAL ··· COMPLETE (or "ERROR at
PD1 PD2
...")
A3 ORIGINAL ··· INCOMPLETE
SIMULATION 41-2
PD SENSOR ADJUSTMENT.
NO ORIGINAL ··· COMPLETE
A3 ORIGINAL ··· COMPLETE (or "ERROR at
PD1 PD2
...")
SIMULATION 65-1